Schneider Electric

Schneider Electric LP1D40008BD IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LP1D40008BD
MPN:
LP1D40008BD
Condition:
New
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Poles Description:
4P
Mercury Free:
Yes
Control Circuit Type:
DC DC standard
Width:
85 mm
Reach Free Of Svhc:
Yes
Country of Origin:
France
Mounting Support:
plate || rail
Contactor Application:
resistive load
Utilisation Category:
AC-1
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz
Circularity Profile:
N/A
Height:
127 mm
Power Dissipation Per Pole:
5.4 W AC-1
Range:
TeSys
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Pvc Free:
Yes
Pollution Degree:
3
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Inrush Power In W:
22-22 W 20°C)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ith] Conventional Free Air Thermal Current:
60 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant
Device Short Name:
LP1D
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Depth:
182 mm
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
Pole Contact Composition:
2 NO + 2 NC
Product Certifications:
UL || CSA || CCC || EAC || UKCA || CB || DNV-GL || RINA || BV || LROS (Lloyds register of shipping)
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Range Of Product:
TeSys Deca
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Warranty:
18 months
[Uc] Control Circuit Voltage:
24 V DC
Overvoltage Category:
III
Flame Retardance:
V1 conforming to UL 94
Product Or Component Type:
contactor
Compatibility Code:
LP1D
Mechanical Robustness:
shocks contactor open 8 Gn for 11 ms) || shocks contactor closed 10 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Hold-In Power Consumption In W:
22-22 W 20°C
Mechanical Durability:
10 Mcycles
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Connections - Terminals:
power circuit: screw clamp terminals 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 2.5-25 mm²
Toxic Heavy Metal Free:
Yes
Protective Cover:
without
Weight:
2.21 kg
Rohs Exemption Information:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V
$509.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 60A resistive load rating. Contactor is supplied with a 24 VDC coil with transient suppressor module. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.17 inches deep. It weighs 4.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose