Schneider Electric

Schneider Electric LP1K0601FD Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NC aux, 110VDC coil

(No reviews yet) Write a Review
SKU:
LP1K0601FD
MPN:
LP1K0601FD
Condition:
New
Weight:
0.225 kg
Ambient Air Temperature For Storage:
-50-80°C
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Range:
TeSys
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Auxiliary Contacts Type:
instantaneous 1 NC
Heat Dissipation:
1.3-1.3 W
Depth:
57 mm
Product Or Component Type:
contactor
Mechanical Durability:
10 Mcycles
Control Circuit Type:
DC standard
Toxic Heavy Metal Free:
Yes
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP1503003EN
Warranty:
18 months
Utilisation Category:
AC-3 || AC-3e || AC-4
Contactor Application:
motor control
Ip Degree Of Protection:
IP2X
Mounting Support:
plate || rail
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Operating Altitude:
6561.68 ft (2000 m) without derating
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Minimum Switching Voltage:
17 V for Signaling circuit
Poles Description:
3P
Auxiliary Contact Composition:
1 NC
Country of Origin:
France
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage Category:
III
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Eu Rohs Directive:
Compliant
Net Weight:
0.225 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
-25-50°C
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Height:
58 mm
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Pole Contact Composition:
3 NO