Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Circularity Profile:
ENVEOLI1503003EN
Toxic Heavy Metal Free:
Yes
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Pole Contact Composition:
3 NO
Contactor Application:
motor control
Sustainable Offer Status:
Green Premium product
Inrush Power In W:
3-3 W 20°C)
Mercury Free:
Yes
Hold-In Power Consumption In W:
3-3 W 20°C
Product Or Component Type:
contactor
Control Circuit Type:
DC standard
Device Short Name:
LP1K
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Net Weight:
0.225 kg
Utilisation Category:
AC-3 || AC-3e || AC-4
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Mounting Support:
rail || plate
Eu Rohs Directive:
Compliant
Maximum Operating Rate:
3600 cyc/h
Reach Free Of Svhc:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Poles Description:
3P
[Uc] Control Circuit Voltage:
110 V DC
Minimum Switching Current:
5 mA for Signaling circuit
Auxiliary Contact Composition:
1 NO
Country of Origin:
Indonesia
Ip Degree Of Protection:
IP2X
Overvoltage Category:
III
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Mechanical Durability:
10 Mcycles
Auxiliary Contacts Type:
instantaneous 1 NO
Heat Dissipation:
1.3-1.3 W
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Environmental Disclosure:
ENVPEP1503003EN
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Warranty:
18 months