- Ambient Air Temperature For Storage:
- -50-80°C
- Hold-In Power Consumption In W:
- 3-3 W 20°C
- Country of Origin:
- Indonesia
- Tightening Torque:
- 0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
- Rohs Exemption Information:
- Yes
- Ip Degree Of Protection:
- IP2X
- Maximum Operating Rate:
- 3600 cyc/h
- Auxiliary Contact Composition:
- 1 NO
- Heat Dissipation:
- 1.3-1.3 W
- Toxic Heavy Metal Free:
- Yes
- Eu Rohs Directive:
- Compliant
- Reach Free Of Svhc:
- Yes
- Ambient Air Temperature For Operation:
- -25-50°C
- [Icw] Rated Short-Time Withstand Current:
- 90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
- Device Short Name:
- LP1K
- Contactor Application:
- motor control
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- [Uc] Control Circuit Voltage:
- 220 V DC
- Inrush Power In W:
- 3-3 W 20°C)
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Weight:
- 0.225 kg
- Motor Power Kw:
- 1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Range:
- TeSys
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Utilisation Category:
- AC-3 || AC-3e || AC-4
- Product Or Component Type:
- contactor
- Depth:
- 57 mm
- Control Circuit Type:
- DC standard
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Poles Description:
- 3P
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Mercury Free:
- Yes
- Mounting Support:
- plate || rail
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Warranty:
- 18 months
- Pole Contact Composition:
- 3 NO
- Net Weight:
- 0.225 kg
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Mechanical Durability:
- 10 Mcycles
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)