Schneider Electric

Schneider Electric LP1K09004BD3 Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V, 20A, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP1K09004BD3
MPN:
LP1K09004BD3
Condition:
New
Overvoltage Category:
III
Operating Altitude:
6561.68 ft (2000 m) without derating
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Circularity Profile:
ENVEOLI1503003EN
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Mercury Free:
Yes
Maximum Operating Rate:
3600 cyc/h
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Pole Contact Composition:
4 NO
Product Or Component Type:
contactor
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Type:
DC standard
Height:
58 mm
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Weight:
0.225 kg
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device Short Name:
LP1K
Poles Description:
4P
Reach Free Of Svhc:
Yes
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Utilisation Category:
AC-1
Sustainable Offer Status:
Green Premium product
Mechanical Durability:
10 Mcycles
Net Weight:
0.225 kg
Contactor Application:
resistive load
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Hold-In Power Consumption In W:
3-3 W 20°C
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Toxic Heavy Metal Free:
Yes
Eu Rohs Directive:
Compliant
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Country of Origin:
Indonesia
Range:
TeSys
Inrush Power In W:
3-3 W 20°C)
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Ip Degree Of Protection:
IP2X
Heat Dissipation:
1.3-1.3 W
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Ambient Air Temperature For Storage:
-50-80°C
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
$102.00

Description

TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with transient suppressor module, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose