Schneider Electric

Schneider Electric LP1K09004ED Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V, 20A, 48VDC coil

(No reviews yet) Write a Review
SKU:
LP1K09004ED
MPN:
LP1K09004ED
Condition:
New
Pole Contact Composition:
4 NO
Net Weight:
0.225 kg
Hold-In Power Consumption In W:
3-3 W 20°C
Overvoltage Category:
III
Device Short Name:
LP1K
Rohs Exemption Information:
Yes
Country of Origin:
France
Eu Rohs Directive:
Compliant
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Reach Free Of Svhc:
Yes
Weight:
0.225 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mounting Support:
rail || plate
Mechanical Durability:
10 Mcycles
Depth:
57 mm
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Heat Dissipation:
1.3-1.3 W
Ambient Air Temperature For Operation:
-25-50°C
Operating Altitude:
6561.68 ft (2000 m) without derating
Inrush Power In W:
3-3 W 20°C)
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Circularity Profile:
ENVEOLI1503003EN
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Product Or Component Type:
contactor
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP1503003EN
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
[Uc] Control Circuit Voltage:
48 V DC
Utilisation Category:
AC-1
Ip Degree Of Protection:
IP2X
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate:
3600 cyc/h
Ambient Air Temperature For Storage:
-50-80°C
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Range:
TeSys
Control Circuit Type:
DC standard
$92.00

Description

TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a 48V DC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose