Schneider Electric

Schneider Electric LP1K09105BD Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 9A, 1 NO aux, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP1K09105BD
MPN:
LP1K09105BD
Condition:
New
Heat Dissipation:
1.3-1.3 W
Product Or Component Type:
contactor
Range:
TeSys
Net Weight:
0.225 kg
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Pole Contact Composition:
3 NO
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Hold-In Power Consumption In W:
3-3 W 20°C
Environmental Disclosure:
ENVPEP1503003EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rohs Exemption Information:
Yes
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Mercury Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ip Degree Of Protection:
IP2X
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Warranty:
18 months
Depth:
57 mm
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Minimum Switching Current:
5 mA for Signaling circuit
Overvoltage Category:
III
Toxic Heavy Metal Free:
Yes
Maximum Operating Rate:
3600 cyc/h
Weight:
0.225 kg
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Circularity Profile:
ENVEOLI1503003EN
Connections - Terminals:
solder pins 0.035 mm)
Eu Rohs Directive:
Compliant
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mounting Support:
printed circuit boards
Control Circuit Type:
DC standard
Country of Origin:
France
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Sustainable Offer Status:
Green Premium product
Height:
58 mm
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Operating Altitude:
6561.68 ft (2000 m) without derating
Minimum Switching Voltage:
17 V for Signaling circuit
Contactor Application:
resistive load || motor control
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
$92.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil, 1NO built-in auxiliary contact, connection by solder pins for printed circuit boards. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).