Schneider Electric

Schneider Electric LP1K1210FD Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 12A, 1 NO aux, 110VDC coil

(No reviews yet) Write a Review
SKU:
LP1K1210FD
MPN:
LP1K1210FD
Condition:
New
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Rohs Exemption Information:
Yes
Depth:
57 mm
Sustainable Offer Status:
Green Premium product
Mounting Support:
rail || plate
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Ambient Air Temperature For Storage:
-50-80°C
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Auxiliary Contacts Type:
instantaneous 1 NO
Poles Description:
3P
Reach Free Of Svhc:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Minimum Switching Voltage:
17 V for Signaling circuit
[Uc] Control Circuit Voltage:
110 V DC
Weight:
0.225 kg
Range:
TeSys
Auxiliary Contact Composition:
1 NO
Ambient Air Temperature For Operation:
-25-50°C
Heat Dissipation:
1.3-1.3 W
Hold-In Power Consumption In W:
3-3 W 20°C
Circularity Profile:
ENVEOLI1503003EN
Toxic Heavy Metal Free:
Yes
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
Motor Power Kw:
3 kW 220...230 V AC 50/60 Hz AC-3 || 5.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 3 kW 220...230 V AC 50/60 Hz AC-3e || 5.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
Environmental Disclosure:
ENVPEP1503003EN
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Product Or Component Type:
contactor
Mechanical Durability:
10 Mcycles
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Insulation Resistance:
> 10 MOhm for Signaling circuit
Inrush Power In W:
3-3 W 20°C)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Overvoltage Category:
III
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Net Weight:
0.225 kg
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Mercury Free:
Yes
[Ie] Rated Operational Current:
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
$106.00