- Utilisation Category:
- AC-3 || AC-3e || AC-1 || AC-4
- Rohs Exemption Information:
- Yes
- Depth:
- 57 mm
- Sustainable Offer Status:
- Green Premium product
- Mounting Support:
- rail || plate
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Ambient Air Temperature For Storage:
- -50-80°C
- Control Circuit Voltage Limits:
- operational: 0.8...1.15 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
- Auxiliary Contacts Type:
- instantaneous 1 NO
- Poles Description:
- 3P
- Reach Free Of Svhc:
- Yes
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Uc] Control Circuit Voltage:
- 110 V DC
- Weight:
- 0.225 kg
- Range:
- TeSys
- Auxiliary Contact Composition:
- 1 NO
- Ambient Air Temperature For Operation:
- -25-50°C
- Heat Dissipation:
- 1.3-1.3 W
- Hold-In Power Consumption In W:
- 3-3 W 20°C
- Circularity Profile:
- ENVEOLI1503003EN
- Toxic Heavy Metal Free:
- Yes
- [Icw] Rated Short-Time Withstand Current:
- 115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
- Motor Power Kw:
- 3 kW 220...230 V AC 50/60 Hz AC-3 || 5.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 3 kW 220...230 V AC 50/60 Hz AC-3e || 5.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
- Environmental Disclosure:
- ENVPEP1503003EN
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Product Or Component Type:
- contactor
- Mechanical Durability:
- 10 Mcycles
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Inrush Power In W:
- 3-3 W 20°C)
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
- Overvoltage Category:
- III
- Rated Breaking Capacity:
- 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Average Impedance:
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Net Weight:
- 0.225 kg
- Operating Time:
- 30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Warranty:
- 18 months
- Mercury Free:
- Yes
- [Ie] Rated Operational Current:
- 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Standards: