Schneider Electric

Schneider Electric LP2K0610BD3 Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP2K0610BD3
MPN:
LP2K0610BD3
Condition:
New
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz || 2.2 kW 380...415 V AC 50/60 Hz || 3 kW 440/690 V AC 50/60 Hz
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc:
Yes
Width:
90 mm
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Depth:
57 mm
Ambient Air Temperature For Operation:
-25-50°C
Device Short Name:
LP2K
Minimum Switching Current:
5 mA for Signaling circuit
Mechanical Durability:
5 Mcycles
Product Name:
TeSys K
[Uc] Control Circuit Voltage:
24 V DC
Protective Treatment:
TC IEC 60068 || TC DIN 50016
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Insulation Resistance:
> 10 MOhm for Signaling circuit
Non Overlap Distance:
0.5 mm
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz || Signaling circuit <= 690 V AC 50/60 Hz
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Maximum Operating Rate:
3600 cyc/h
Country of Origin:
France
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Device Application:
control
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Operating Altitude:
6561.68 ft (2000 m) without derating
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.1...0.75 Uc (at <50°C)
Ip Degree Of Protection:
IP20 VDE 0106
Overvoltage Category:
III
Hold-In Power Consumption In W:
3-3 W 20°C
Pole Contact Composition:
3 NO
Sustainable Offer Status:
Green Premium product
Mechanical Robustness:
shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068
Net Weight:
0.48 kg
Heat Dissipation:
3-3 W
Interlocking Type:
mechanical
Auxiliary Contact Composition:
1 NO
Range:
TeSys
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
Auxiliary Contacts Type:
instantaneous 1 NO
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Device Presentation:
preassembled with reversing power busbar
Ambient Air Temperature For Storage:
-50-80°C
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Mounting Support:
rail || plate
Utilisation Category:
AC-3 || AC-3e || AC-4
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
$187.00

Description

TeSys K reversing contactor, 3 poles (3NO), for motor control applications up to 6A/690V AC-3 (2.2kW@400V). It provides 24V DC coil with transient suppressor module, 2NO built-in auxiliary contacts, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Compact (90mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose