Schneider Electric

Schneider Electric LP2K09004BD Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP2K09004BD
MPN:
LP2K09004BD
Condition:
New
Depth:
57 mm
Eu Rohs Directive:
Compliant
Interlocking Type:
mechanical
Range:
TeSys
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Rated Breaking Capacity:
110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Operating Altitude:
6561.68 ft (2000 m) without derating
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mechanical Robustness:
shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068
Warranty:
18 months
Reach Free Of Svhc:
Yes
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Ip Degree Of Protection:
IP20 VDE 0106
Weight:
0.48 kg
[Ie] Rated Operational Current:
20 A (at <50°C) at <= 440 V AC AC-1 for power circuit || 16 A (at <70°C) at 690 V AC AC-1 for power circuit
Device Short Name:
LP2K
Irms Rated Making Capacity:
110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947
Country of Origin:
France
Mounting Support:
rail || plate
Toxic Heavy Metal Free:
Yes
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
[Ith] Conventional Free Air Thermal Current:
20 A (at 50°C) for power circuit
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Hold-In Power Consumption In W:
3-3 W 20°C
Product Name:
TeSys K
Overvoltage Category:
III
Control Circuit Type:
DC standard
Heat Dissipation:
3-3 W
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device Presentation:
preassembled with reversing power busbar
Poles Description:
4P
Utilisation Category:
AC-1
Width:
90 mm
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.1...0.75 Uc (at <50°C)
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Contactor Application:
resistive load
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Rohs Exemption Information:
Yes
Operating Time:
30...40 ms coil energisation and NO closing || 10 ms coil de-energisation and NO opening
Mechanical Durability:
5 Mcycles
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Device Application:
control
Environmental Disclosure:
ENVPEP1503003EN
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
$202.00