Schneider Electric LP4K090087BW3 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V, 20A, 24VDC coil
SKU:
LP4K090087BW3
UPC:
MPN:
LP4K090087BW3
Condition:
New
Device Short Name:
LP4K
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Heat Dissipation:
1.8-1.8 W
Circularity Profile:
ENVEOLI1503003EN
Toxic Heavy Metal Free:
Yes
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
[Uc] Control Circuit Voltage:
24 V DC
Weight:
0.235 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Product Or Component Type:
contactor
Utilisation Category:
AC-1
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Ambient Air Temperature For Storage:
-50-80°C
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with transient suppressor module, without built-in auxiliary contact,...
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil, without built-in auxiliary contact, connection by screw clamp...
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a low consumption 24V DC coil with transient suppressor module, without built-in...
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V DC coil, without built-in auxiliary contact, connection by solder pins for...
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a low consumption 48V DC coil with transient suppressor module, without built-in...
TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V DC coil, without built-in auxiliary contact, connection by screw clamp...
TeSys K contactor, 4 poles (4NO), for non-inductive load control applications up to 20A/690V AC-1. It provides a low consumption 24V DC coil with transient suppressor module, without built-in...