Schneider Electric

Schneider Electric LP4K09013BW3 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 9A, 1 NC aux, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP4K09013BW3
MPN:
LP4K09013BW3
Condition:
New
Ambient Air Temperature For Operation:
-25-50°C
Connections - Terminals:
spring terminals 1 0.75-1.5 mm²solid || spring terminals 1 0.75-1.5 mm²flexible without cable end || spring terminals 2 0.75-1.5 mm²flexible without cable end
Control Circuit Type:
DC wide range
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Minimum Switching Voltage:
17 V for Signaling circuit
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Contactor Application:
motor control || resistive load
Sustainable Offer Status:
Green Premium product
Depth:
57 mm
Toxic Heavy Metal Free:
Yes
Mechanical Durability:
30 Mcycles
Auxiliary Contact Composition:
1 NC
Device Short Name:
LP4K
Insulation Resistance:
> 10 MOhm for Signaling circuit
Pole Contact Composition:
3 NO
Mercury Free:
Yes
Maximum Operating Rate:
3600 cyc/h
Control Circuit Voltage Limits:
operational: 0.7...1.3 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Hold-In Power Consumption In W:
1.8-1.8 W 20°C
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Mounting Support:
rail || plate
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Average Impedance:
3 mOhm - Ith 16 A 50 Hz for power circuit
Overvoltage Category:
III
Reach Free Of Svhc:
Yes
Poles Description:
3P
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
[Ith] Conventional Free Air Thermal Current:
16 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
[Uc] Control Circuit Voltage:
24 V DC
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Environmental Disclosure:
ENVPEP1503003EN
Circularity Profile:
ENVEOLI1503003EN
Weight:
0.235 kg
Operating Time:
10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Range:
TeSys
Inrush Power In W:
1.8-1.8 W 20°C)
$110.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NC built-in auxiliary contact, connection by spring terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose