[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Coil Technology:
built-in bidirectional peak limiting diode suppressor
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Contactor Application:
resistive load || motor control
Range:
TeSys
Product Or Component Type:
contactor
Insulation Resistance:
> 10 MOhm for Signaling circuit
Depth:
57 mm
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Mercury Free:
Yes
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Environmental Disclosure:
ENVPEP1503003EN
Ambient Air Temperature For Operation:
-25-50°C
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Operating Time:
10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Sustainable Offer Status:
Green Premium product
Control Circuit Voltage Limits:
operational: 0.7...1.3 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Eu Rohs Directive:
Compliant
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
Device Short Name:
LP4K
Minimum Switching Voltage:
17 V for Signaling circuit
Inrush Power In W:
1.8-1.8 W 20°C)
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Toxic Heavy Metal Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Rohs Exemption Information:
Yes
Net Weight:
0.235 kg
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Minimum Switching Current:
5 mA for Signaling circuit
Auxiliary Contact Composition:
1 NO
Ip Degree Of Protection:
IP2X
Heat Dissipation:
1.8-1.8 W
Mechanical Durability:
30 Mcycles
Hold-In Power Consumption In W:
1.8-1.8 W 20°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Warranty:
18 months
[Uc] Control Circuit Voltage:
24 V DC
Overvoltage Category:
III
$110.00

Description

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).