Schneider Electric

Schneider Electric LP4K12015BW3 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 12A, 1 NC aux, 24VDC coil

(No reviews yet) Write a Review
SKU:
LP4K12015BW3
MPN:
LP4K12015BW3
Condition:
New
Rated Breaking Capacity:
110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conforming to IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Toxic Heavy Metal Free:
Yes
Reach Free Of Svhc:
Yes
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Depth:
57 mm
Net Weight:
0.235 kg
Hold-In Power Consumption In W:
1.8-1.8 W 20°C
[Ie] Rated Operational Current:
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Electrical Durability:
1.3 Mcycles 12 A AC-3 <= 440 V || 1.3 Mcycles 12 A AC-3e <= 440 V || 0.3 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 72 A AC-4 <= 440 V
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Altitude:
6561.68 ft (2000 m) without derating
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
Sustainable Offer Status:
Green Premium product
Control Circuit Type:
DC wide range
Minimum Switching Current:
5 mA for Signaling circuit
Connections - Terminals:
solder pins 0.035 mm)
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Heat Dissipation:
1.8-1.8 W
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Poles Description:
3P
Overvoltage Category:
III
Range:
TeSys
Insulation Resistance:
> 10 MOhm for Signaling circuit
Warranty:
18 months
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1503003EN
Weight:
0.235 kg
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Control Circuit Voltage Limits:
operational: 0.7...1.3 Uc (at <50°C) || drop-out: >= 0.10 Uc (at <50°C)
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Pole Contact Composition:
3 NO
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Auxiliary Contact Composition:
1 NC
Ambient Air Temperature For Storage:
-50-80°C
Contactor Application:
resistive load || motor control
Ambient Air Temperature For Operation:
-25-50°C
[Uc] Control Circuit Voltage:
24 V DC
Inrush Power In W:
1.8-1.8 W 20°C)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Country of Origin:
Indonesia
Motor Power Kw:
3 kW 220...230 V AC 50/60 Hz AC-3 || 5.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 3 kW 220...230 V AC 50/60 Hz AC-3e || 5.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
Maximum Operating Rate:
3600 cyc/h
$126.00