- Mounting Support:
- plate || rail
- Sustainable Offer Status:
- Green Premium product
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Utilisation Category:
- AC-1 || AC-3 || AC-4 || AC-3e
- Rated Breaking Capacity:
- 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Product Name:
- TeSys K
- Width:
- 90 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Toxic Heavy Metal Free:
- Yes
- Non Overlap Distance:
- 0.5 mm
- Mercury Free:
- Yes
- Control Circuit Voltage Limits:
- operational: 0.7...1.30 Uc (at <50°C) || drop-out: 0.1...0.7 Uc (at <50°C)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Control Circuit Type:
- DC low consumption
- Environmental Disclosure:
- ENVPEP1503003EN
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Circularity Profile:
- ENVEOLI1503003EN
- Motor Power Kw:
- 2.2 kW 220...230 V AC 50/60 Hz || 4 kW 380...415 V AC 50/60 Hz || 4 kW 440 V AC 50/60 Hz || 4 kW 480 V AC 50/60 Hz || 4 kW 500...600 V AC 50/60 Hz || 4 kW 660...690 V AC 50/60 Hz
- Contactor Application:
- motor control || resistive load
- Auxiliary Contacts Type:
- instantaneous 1 NC
- Interlocking Type:
- mechanical
- [Uc] Control Circuit Voltage:
- 24 V DC
- Depth:
- 57 mm
- Associated Fuse Rating:
- 25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- [Ith] Conventional Free Air Thermal Current:
- 16 A (at 50°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Country of Origin:
- France
- Ambient Air Temperature For Operation:
- -25-50°C
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Reach Free Of Svhc:
- Yes
- Eu Rohs Directive:
- Compliant
- Rohs Exemption Information:
- Yes
- Inrush Power In W:
- 1.8-1.8 W 20°C)
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- [Ui] Rated Insulation Voltage:
- power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
- Auxiliary Contact Composition:
- 1 NC
- Mechanical Durability:
- 5 Mcycles
- Product Or Component Type:
- reversing contactor
- Overvoltage Category:
- III
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Maximum Operating Rate:
- 3600 cyc/h
- Irms Rated Making Capacity:
- 110 A AC for power circuit conforming to NF C 63-110 || 110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
- Pole Contact Composition:
- 3 NO