Schneider Electric

Schneider Electric LR3D3557 TeSys Deca thermal overload relays,37...50A,class 20

(No reviews yet) Write a Review
SKU:
LR3D3557
MPN:
LR3D3557
Condition:
New
Flame Retardance:
V1 conforming to UL 94
Country of Origin:
United States
Toxic Heavy Metal Free:
Yes
Weight:
0.535 kg
Relay Application:
motor protection
Network Frequency:
0...400 Hz
Dielectric Strength:
1.89 kV 50 Hz IEC 60947-1
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Range:
TeSys
Product Or Component Type:
non differential thermal overload relay
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Environmental Disclosure:
ENVPEP110101EN
Reach Free Of Svhc:
Yes
Mercury Free:
Yes
Product Certifications:
IEC || UL || CSA || CCC || EAC || BV || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Circularity Profile:
ENVEOLI1101001
Mechanical Robustness:
vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 9 N.m screw clamp terminals
Temperature Compensation:
-20-60°C
Warranty:
18 months
Depth:
121 mm
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Net Weight:
0.535 kg
Associated Fuse Rating:
4 A gG for Signaling circuit || 4 A BS for Signaling circuit
Product Name:
TeSys LRD || TeSys Deca
Thermal Overload Class:
class 20 IEC 60947-4-1
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Thermal Protection Adjustment Range:
37-50 A
Climatic Withstand:
IACS E10
Ambient Air Temperature For Storage:
-60-70°C
[Ue] Rated Operational Voltage:
690 V AC 0...400 Hz power circuit IEC 60947-4-1
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
[Ui] Rated Insulation Voltage:
power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
Rohs Exemption Information:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Control Type:
Red push-button stop || Blue push-button reset
Product Compatibility:
LC1D95 || LC1D80
Device Short Name:
LR3D
Auxiliary Contact Composition:
1 NO + 1 NC
Mounting Support:
plate, with specific accessories || rail, with specific accessories || under contactor
Network Type:
AC || DC
Connections - Terminals:
power circuit screw clamp terminals 1 4-35 mm² flexible without cable end || power circuit screw clamp terminals 1 4-35 mm² flexible with cable end || power circuit screw clamp terminals 1 4-35 mm² solid without cable end || control circuit screw
$107.00

Description

LR3D3557 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 22kW@400V thanks to a thermal range 37-50A , a tripping class 20, for use with unbalanced loads. LR3D3557 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 37-50A and tripping class 20, it protects unbalanced loads and motors 22kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, for use with unbalanced loads (non differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D80 and D95 to form a compact starter. Light and compact, 70mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
View AllClose