Schneider Electric

Schneider Electric LR9D08KITD09BD Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay

(No reviews yet) Write a Review
SKU:
LR9D08KITD09BD
MPN:
LR9D08KITD09BD
Condition:
New
Ip Degree Of Protection:
front face IP20 IEC 60529 || front face IP20 VDE 0106
Depth:
79.9 mm
Time Range:
1.5...4 min - automatic reset time
[Ui] Rated Insulation Voltage:
power circuit 1000 V || Signaling circuit 690 V
Sustainable Offer Status:
Green Premium product
Protective Treatment:
TH IEC 60068-2-30
Mounting Support:
plate || rail
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Power Dissipation Per Pole:
1.56 W AC-1 || 0.2 W AC-3
Product Certifications:
LROS (Lloyds register of shipping) || CSA || UL || GOST || DNV || CCC || GL || BV || RINA
Minimum Switching Current:
5 mA for Signaling circuit
Phase Failure Sensitivity:
phase difference > 40% 3-3 s IEC 60947-4-1
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
[Ith] Conventional Free Air Thermal Current:
25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Tripping Threshold:
1.25 In IEC 60947-4-1
Operating Time:
53.55...72.45 ms closing || 16...24 ms opening
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Minimum Switching Voltage:
17 V for Signaling circuit
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Connections - Terminals:
control circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end || power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end
Weight:
0.48 kg
Range:
TeSys
Power Consumption In W:
300 mW
Time Constant:
28 ms
Mounting Support:
under contactor || plate, with specific accessories || rail, with specific accessories
Mechanical Robustness:
vibrations 10...150 Hz 6 Gn) IEC 60068-2-6 || shocks 11 ms 15 gn) IEC 60068-2-7
Eu Rohs Directive:
Compliant with Exemptions
Standards:
UL 60947-4-1 || IEC 60947-4-1 || GB 14048.4 || CSA C22.2
Rohs Exemption Information:
Yes
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Height:
77 mm
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Poles Description:
3P
Relay Application:
motor protection
Control Circuit Voltage Limits:
drop-out 0.1...0.25 Uc DC 60°C) || operational 0.7...1.25 Uc DC 60°C)
Inrush Power In W:
5.4-5.4 W 20°C)
Power Range:
1.1-2 kW 200-240 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 4-6 kW 480-500 V 3 phase
Motor Starter Type:
direct on-line contactor
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Ambient Air Temperature For Operation:
-5-60°C
Circularity Profile:
ENVEOLI1502001EN
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Contact Compatibility:
M4
Pollution Degree:
3
[Uc] Control Circuit Voltage:
24 V DC
Maximum Horse Power Rating:
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phas
Operating Altitude:
6561.68 ft (2000 m) without derating
$95.00

Description

TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
View AllClose