Schneider Electric LR9D08KITD09BD Tesys motor starter kit, LC1D09BD contactor, LR9D08 thermal overload relay
Schneider Electric
$95.00
TeSys motor starter kits combine a TeSys LC1D contactor and a TeSys LR9D overload relay to make an IEC starter. This starter has a LC1D09BD contactor and a LR9D08 electronic overload relay. The LC1D09BD contactor has a 9 ampere resistive and horsepower ratings. The LR9D08 electronic overload relay has a current setting of 1.6 to 8 amperes. This starter is UL listed and CSA certified.
- Ip Degree Of Protection:
- front face IP20 IEC 60529 || front face IP20 VDE 0106
- Depth:
- 79.9 mm
- Time Range:
- 1.5...4 min - automatic reset time
- [Ui] Rated Insulation Voltage:
- power circuit 1000 V || Signaling circuit 690 V
- Sustainable Offer Status:
- Green Premium product
- Protective Treatment:
- TH IEC 60068-2-30
- Mounting Support:
- plate || rail
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV
- Power Dissipation Per Pole:
- 1.56 W AC-1 || 0.2 W AC-3
- Product Certifications:
- LROS (Lloyds register of shipping) || CSA || UL || GOST || DNV || CCC || GL || BV || RINA
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Phase Failure Sensitivity:
- phase difference > 40% 3-3 s IEC 60947-4-1
- Tightening Torque:
- power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
- [Ith] Conventional Free Air Thermal Current:
- 25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Tripping Threshold:
- 1.25 In IEC 60947-4-1
- Operating Time:
- 53.55...72.45 ms closing || 16...24 ms opening
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Connections - Terminals:
- control circuit screw clamp terminals 1 2.5-2.5 mm² solid or flexible - without cable end || power circuit screw clamp terminals 1 16-16 mm² solid or flexible - without cable end
- Weight:
- 0.48 kg
- Range:
- TeSys
- Power Consumption In W:
- 300 mW
- Time Constant:
- 28 ms
- Mounting Support:
- under contactor || plate, with specific accessories || rail, with specific accessories
- Mechanical Robustness:
- vibrations 10...150 Hz 6 Gn) IEC 60068-2-6 || shocks 11 ms 15 gn) IEC 60068-2-7
- Eu Rohs Directive:
- Compliant with Exemptions
- Standards:
- UL 60947-4-1 || IEC 60947-4-1 || GB 14048.4 || CSA C22.2
- Rohs Exemption Information:
- Yes
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
- Height:
- 77 mm
- Mechanical Robustness:
- vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed4 Gn, 5...300 Hz || shocks contactor open10 Gn for 11 ms || shocks contactor closed15 Gn for 11 ms
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Poles Description:
- 3P
- Relay Application:
- motor protection
- Control Circuit Voltage Limits:
- drop-out 0.1...0.25 Uc DC 60°C) || operational 0.7...1.25 Uc DC 60°C)
- Inrush Power In W:
- 5.4-5.4 W 20°C)
- Power Range:
- 1.1-2 kW 200-240 V 3 phase || 2.2-3 kW 380-440 V 3 phase || 4-6 kW 380-440 V 3 phase || 4-6 kW 480-500 V 3 phase
- Motor Starter Type:
- direct on-line contactor
- Permissible Ambient Air Temperature Around The Device:
- -40-70°C at Uc
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Ambient Air Temperature For Operation:
- -5-60°C
- Circularity Profile:
- ENVEOLI1502001EN
- [Ith] Conventional Free Air Thermal Current:
- 5 A Signaling circuit
- Contact Compatibility:
- M4
- Pollution Degree:
- 3
- [Uc] Control Circuit Voltage:
- 24 V DC
- Maximum Horse Power Rating:
- 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 50/60 Hz for 3 phas
- Operating Altitude:
- 6561.68 ft (2000 m) without derating