Schneider Electric

Schneider Electric LRD06L TeSys Deca thermal overload relays - 1...1.6 A - class 20

(No reviews yet) Write a Review
SKU:
LRD06L
MPN:
LRD06L
Condition:
New
Sustainable Offer Status:
Green Premium product
Product Certifications:
IEC || UL || CSA || EAC || ABS || ATEX INERIS || UKCA
Associated Fuse Rating:
4 A gG for Signaling circuit || 4 A BS for Signaling circuit
Rohs Exemption Information:
Yes
Permissible Current:
3 A 120 V AC-15 Signaling circuit || 0.22 A 125 V DC-13 Signaling circuit
Country of Origin:
Mexico
Dielectric Strength:
1.89 kV 50 Hz IEC 60947-1
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
Network Type:
AC || DC
Eu Rohs Directive:
Compliant
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Storage:
-60-70°C
Thermal Protection Adjustment Range:
1-1.6 A
Weight:
0.144 kg
Circularity Profile:
ENVEOLI0802006
Environmental Disclosure:
ENVPEP080206EN
Sustainable Packaging:
Yes
Warranty:
18 months
Control Type:
Red push-button stop || Blue push-button reset
Product Compatibility:
LC1D25 || LC1D09 || LC1D32 || LC1D12 || LC1D18 || LC1D38
Thermal Overload Class:
class 20 IEC 60947-4-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Net Weight:
0.144 kg
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
Device Short Name:
LRD
Mercury Free:
Yes
Network Frequency:
0...400 Hz
Relay Application:
motor protection
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Product Name:
TeSys LRD || TeSys Deca
Range:
TeSys || TeSys Deca
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Climatic Withstand:
IACS E10
Temperature Compensation:
-20-60°C
Mounting Support:
plate, with specific accessories || rail, with specific accessories || under contactor
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || EN 50495
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Toxic Heavy Metal Free:
Yes
Connections - Terminals:
control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit
Depth:
76 mm
Product Or Component Type:
differential thermal overload relay
$60.00

Description

LRD06L is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 0.25-0.55kW@400V thanks to a thermal range 1-1.6A, a tripping class 20 and phase unbalance protection. LRD06L is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 1-1.6A, a tripping class 20 and phase unbalance detection, it protects motors 0.25-0.55kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D09-D38 to form a compact starter. Light and compact, 45mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
View AllClose