Schneider Electric LRD33696 TeSys Deca thermal overload relays , 110...140A , class 10A
SKU:
LRD33696
UPC:
MPN:
LRD33696
Condition:
New
Connections - Terminals:
power circuit screw clamp terminals 1 4-35 mm² flexible without cable end || power circuit screw clamp terminals 1 4-35 mm² flexible with cable end || power circuit screw clamp terminals 1 4-35 mm² solid without cable end || control circuit screw
Circularity Profile:
ENVEOLI1101001
Reach Free Of Svhc:
Yes
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5 || EN 50495
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Network Type:
AC || DC
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
Associated Fuse Rating:
4 A gG for Signaling circuit || 4 A BS for Signaling circuit
Thermal Protection Adjustment Range:
110-140 A
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Thermal Overload Class:
class 10A IEC 60947-4-1
Permissible Current:
0.72 A 500 V AC-15 Signaling circuit || 0.06 A 440 V DC-13 Signaling circuit
LRD4369 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 63kW@400V thanks to a thermal range 110-140A, a tripping class 10A and...
TeSys LRD thermal overload relay, 13A/690V, thermal setting range 9-13A, tripping class 10A, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure and load unbalance...
TeSys LRD thermal overload relay, 2.5A/690V, thermal setting range 1.6-2.5A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Differential device with phase failure and load...
LR3D35 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 15-18.5kW@400V thanks to a thermal range 30-38A , a tripping class 10A,...
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance...
TeSys LRD thermal overload relay, 2.5A/690V, thermal setting range 1.6-2.5A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Non differential device, it can be used with unbalanced...
TeSys LRD thermal overload relay, 1A/690V, thermal setting range 0.63-1A, tripping class 10A, for protection of 3-phase motors 0.25-0.37kW@400V. Non differential device, it can be used with...
TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential...
TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential...