Schneider Electric

Schneider Electric LRD4367 TeSys Deca thermal overload relays , 95...120A , class 10A

(No reviews yet) Write a Review
SKU:
LRD4367
MPN:
LRD4367
Condition:
New
[Ue] Rated Operational Voltage:
1000 V AC 0...400 Hz power circuit IEC 60947-4-1
Warranty:
18 months
Product Or Component Type:
differential thermal overload relay
Range:
TeSys
Associated Fuse Rating:
4 A gG for Signaling circuit || 4 A BS for Signaling circuit
Rohs Exemption Information:
Yes
Ambient Air Temperature For Storage:
-60-70°C
Control Type:
Red push-button stop || Blue push-button reset
Phase Failure Sensitivity:
tripping current 130 % of Ir on two phase, the last one at 0
Sustainable Offer Status:
Green Premium product
Network Frequency:
0...400 Hz
Dielectric Strength:
2.2 kV 50 Hz IEC 60947-1
[Ith] Conventional Free Air Thermal Current:
5 A Signaling circuit
Flame Retardance:
V1 conforming to UL 94
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5 || EN 50495
Thermal Protection Adjustment Range:
95-120 A
[Ui] Rated Insulation Voltage:
power circuit 1000 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL
Environmental Disclosure:
ENVPEP110101EN
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Auxiliary Contact Composition:
1 NO + 1 NC
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Thermal Overload Class:
class 10A IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Permissible Current:
0.06 A 440 V DC-13 Signaling circuit || 0.12 A 600 V AC-15 Signaling circuit
Device Short Name:
LRD
Mechanical Robustness:
vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals || power circuit 9 N.m screw clamp terminals
Circularity Profile:
ENVEOLI1101001
Temperature Compensation:
-20-60°C
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Country of Origin:
France
Connections - Terminals:
power circuit screw clamp terminals 1 4-35 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit
Relay Application:
motor protection
Tripping Threshold:
1.14 +/- 0.06 Ir IEC 60947-4-1
Product Compatibility:
LC1D150 || LC1D115
Weight:
0.9 kg
Reach Free Of Svhc:
Yes
Depth:
132 mm
Product Name:
TeSys LRD || TeSys Deca
Mounting Support:
plate, with specific accessories || rail, with specific accessories || under contactor
Net Weight:
0.9 kg
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX INERIS
Network Type:
AC || DC
Climatic Withstand:
IACS E10
Toxic Heavy Metal Free:
Yes
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Operation:
-20-60°C without derating IEC 60947-4-1
$362.00

Description

LRD4367 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 55kW@400V thanks to a thermal range 95-120A, a tripping class 10A and phase unbalance protection. LRD4367 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 95-120A, a tripping class 10A and phase unbalance detection, it protects motors 55kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D115 and D150 to form a compact starter. Light and compact, 120mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).
View AllClose