Schneider Electric

Schneider Electric LTMR08MBD Motor Management, TeSys T, motor controller, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC

(No reviews yet) Write a Review
SKU:
LTMR08MBD
MPN:
LTMR08MBD
Condition:
New
Circularity Profile:
ENVEOLI100411EN_V2
Measurement Accuracy:
5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Load Current:
5 A 250 V AC logic output || 5 A 30 V DC logic output
Maximum Operating Rate:
1800 cyc/h
Pollution Degree:
3
Standards:
IACS E10 || EN 60947-4-1 || UL 508 || CSA C22.2 No 14 || IEC 60947-4-1
Protective Treatment:
12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Permissible Power:
480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Pvc Free:
Yes
Ip Degree Of Protection:
IP20
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Contacts Type And Composition:
1 NO + 1 NC fault signal || 3 NO
Short-Circuit Withstand:
100 kA conforming to EN/IEC 60947-4-1
Product Name:
TeSys T
Eu Rohs Directive:
Compliant with Exemptions
Fire Resistance:
650°C EN/IEC 60695-2-12 || 960°C UL 94
Electromagnetic Compatibility:
electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay ou
Supply Voltage Limits:
20.4-26.24 V DC
Logic Input Number:
6
Connection Pitch:
5.08 mm
Sustainable Offer Status:
Green Premium product
Current State 1 Guaranteed:
logic input < 15 V 2...15 mA 15 ms
Net Weight:
0.53 kg
Current State 0 Guaranteed:
logic input < 5 V <= 15 mA 5 ms
Device Application:
equipment monitoring and control
Overvoltage Category:
III
Network And Machine Diagnosis Type:
running hours counter/operating time || trip history information || phase fault and earth fault trip counters || fault recording || waiting time after overload tripping || remaining operating time before overload tripping || trip context information
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Halogen Content Performance:
Halogen free plastic parts product
Connections - Terminals:
control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
Product Or Component Type:
motor controller
Input Current:
7 mA
Rohs Exemption Information:
Yes
[Us] Rated Supply Voltage:
24 V DC
Depth:
122.5 mm
Range:
TeSys
Bus Type:
Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
Communication Port Protocol:
Modbus
Protection Type:
phase unbalance || locked rotor || power factor variation || load fluctuation || overload || overload (long time) || phase failure || thermal protection || thermal overload protection || earth-leakage protection || reverse polarity protection
Compatibility Code:
LTMR
Current Consumption:
56...127 mA
[Uimp] Rated Impulse Withstand Voltage:
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Metering Type:
average current Iavg || earth-fault current || phase current I1, I2, I3 RMS || imbalance current || temperature
Maximum Operating Frequency:
2 Hz
[Ui] Rated Insulation Voltage:
690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Operating Altitude:
<= 6561.68 ft (2000 m) without derating
$1,012.50