Schneider Electric LTMR08MBD Motor Management, TeSys T, motor controller, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC
Schneider Electric
$1,012.50
Motor Management, TeSys T, motor controller, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24VDC
- Circularity Profile:
- ENVEOLI100411EN_V2
- Measurement Accuracy:
- 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
- Load Current:
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Maximum Operating Rate:
- 1800 cyc/h
- Pollution Degree:
- 3
- Standards:
- IACS E10 || EN 60947-4-1 || UL 508 || CSA C22.2 No 14 || IEC 60947-4-1
- Protective Treatment:
- 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
- Permissible Power:
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Pvc Free:
- Yes
- Ip Degree Of Protection:
- IP20
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Contacts Type And Composition:
- 1 NO + 1 NC fault signal || 3 NO
- Short-Circuit Withstand:
- 100 kA conforming to EN/IEC 60947-4-1
- Product Name:
- TeSys T
- Eu Rohs Directive:
- Compliant with Exemptions
- Fire Resistance:
- 650°C EN/IEC 60695-2-12 || 960°C UL 94
- Electromagnetic Compatibility:
- electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay ou
- Supply Voltage Limits:
- 20.4-26.24 V DC
- Logic Input Number:
- 6
- Connection Pitch:
- 5.08 mm
- Sustainable Offer Status:
- Green Premium product
- Current State 1 Guaranteed:
- logic input < 15 V 2...15 mA 15 ms
- Net Weight:
- 0.53 kg
- Current State 0 Guaranteed:
- logic input < 5 V <= 15 mA 5 ms
- Device Application:
- equipment monitoring and control
- Overvoltage Category:
- III
- Network And Machine Diagnosis Type:
- running hours counter/operating time || trip history information || phase fault and earth fault trip counters || fault recording || waiting time after overload tripping || remaining operating time before overload tripping || trip context information
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Halogen Content Performance:
- Halogen free plastic parts product
- Connections - Terminals:
- control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
- Product Or Component Type:
- motor controller
- Input Current:
- 7 mA
- Rohs Exemption Information:
- Yes
- [Us] Rated Supply Voltage:
- 24 V DC
- Depth:
- 122.5 mm
- Range:
- TeSys
- Bus Type:
- Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
- Communication Port Protocol:
- Modbus
- Protection Type:
- phase unbalance || locked rotor || power factor variation || load fluctuation || overload || overload (long time) || phase failure || thermal protection || thermal overload protection || earth-leakage protection || reverse polarity protection
- Compatibility Code:
- LTMR
- Current Consumption:
- 56...127 mA
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
- Metering Type:
- average current Iavg || earth-fault current || phase current I1, I2, I3 RMS || imbalance current || temperature
- Maximum Operating Frequency:
- 2 Hz
- [Ui] Rated Insulation Voltage:
- 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
- Operating Altitude:
- <= 6561.68 ft (2000 m) without derating