The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Uimp] Rated Impulse Withstand Voltage:
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Load Current:
5 A 250 V AC logic output || 5 A 30 V DC logic output
Electromagnetic Compatibility:
electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay ou
Circularity Profile:
ENVEOLI100411EN_V2
Logic Input Number:
6
Pvc Free:
Yes
Connection Pitch:
5.08 mm
Metering Type:
earth-fault current || average current Iavg || imbalance current || phase current I1, I2, I3 RMS || temperature
Mechanical Robustness:
vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
[Ui] Rated Insulation Voltage:
690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Product Or Component Type:
motor controller
Height:
61 mm
Standards:
IACS E10 || EN 60947-4-1 || IEC 60947-4-1 || UL 508 || CSA C22.2 No 14
Web Services:
web server
Product Name:
TeSys T
Weight:
0.53 kg
Network And Machine Diagnosis Type:
motor control command recording || running hours counter/operating time || trip history information || fault recording || starting current and time || phase fault and earth fault trip counters || remaining operating time before overload tripping || w
Operating Altitude:
<= 6561.68 ft (2000 m) without derating
Measurement Accuracy:
5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Maximum Operating Rate:
1800 cyc/h
Range:
TeSys
Input Current:
7 mA
Connections - Terminals:
control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
Short-Circuit Withstand:
100 kA conforming to EN/IEC 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP060308EN_V2
Communication Port Protocol:
Profibus DP
Contacts Type And Composition:
1 NO + 1 NC fault signal || 3 NO
Eu Rohs Directive:
Compliant with Exemptions
Bus Type:
Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A || Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A
The LTMR08PFM is a motor management relay developed by Schneider Electric. It is a versatile and reliable device designed to provide comprehensive protection and control for motors. This compact...
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes...
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes...
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while...
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes...
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes...