Schneider Electric

Schneider Electric LTMR100DBD Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 5 to 100A, 24VDC

(No reviews yet) Write a Review
SKU:
LTMR100DBD
MPN:
LTMR100DBD
Condition:
New
Measurement Current:
5-100 A
Logic Input Number:
6
[Ui] Rated Insulation Voltage:
690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Product Certifications:
RMRoS || ABS || NOM || KERI || RINA || BV || CCC || C-tick || CSA || EAC || ATEX || UL || GL || DNV || LROS (Lloyds register of shipping)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Halogen Content Performance:
Halogen free plastic parts product
[Uimp] Rated Impulse Withstand Voltage:
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Measurement Accuracy:
5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
Connections - Terminals:
control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
Warranty:
18 months
Net Weight:
0.53 kg
Protective Treatment:
12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Network And Machine Diagnosis Type:
running hours counter/operating time || starting current and time || trip context information || remaining operating time before overload tripping || fault recording || phase fault and earth fault trip counters || event recording || trip history info
Country of Origin:
China
Operating Altitude:
<= 6561.68 ft (2000 m) without derating
Contacts Type And Composition:
1 NO + 1 NC fault signal || 3 NO
Bus Type:
DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
Range:
TeSys
Device Short Name:
LTMR
Pollution Degree:
3
Supply Voltage Limits:
20.4-26.24 V DC
Fire Resistance:
650°C EN/IEC 60695-2-12 || 960°C UL 94
Mercury Free:
Yes
Pvc Free:
Yes
Ambient Air Temperature For Storage:
-40-80°C
Device Application:
equipment monitoring and control
Ip Degree Of Protection:
IP20
Communication Port Protocol:
DeviceNet
Depth:
122.5 mm
Rohs Exemption Information:
Yes
[Us] Rated Supply Voltage:
24 V DC
Tightening Torque:
control circuit 0.5-0.6 N.m flat 3 mm
Maximum Operating Rate:
1800 cyc/h
Sustainable Offer Status:
Green Premium product
Standards:
IEC 60947-4-1 || CSA C22.2 No 14 || EN 60947-4-1 || IACS E10 || UL 508
Short-Circuit Withstand:
100 kA conforming to EN/IEC 60947-4-1
Input Current:
7 mA
Environmental Disclosure:
ENVPEP060308EN_V2
Load Current:
5 A 250 V AC logic output || 5 A 30 V DC logic output
Connection Pitch:
5.08 mm
Permissible Power:
480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Ambient Air Temperature For Operation:
-20-60°C
Web Services:
web server
Product Name:
TeSys T
Current Consumption:
56...127 mA
Current State 0 Guaranteed:
logic input < 5 V <= 15 mA 5 ms
$850.00