TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Profibus DP protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 1.35 to 27 amperes. 120 to 240 VAC is used to power this controller. Controller is 2.40 inches tall, 3.58 inches wide and 4.82 inches deep. Controller weighs 1.17 lbs. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
- Circularity Profile:
- ENVEOLI100411EN_V2
- Protection Type:
- load fluctuation || thermal protection || locked rotor || reverse polarity protection || phase unbalance || earth-leakage protection || overload (long time) || thermal overload protection || overload || phase failure || power factor variation
- Product Certifications:
- BV || CSA || CCC || EAC || NOM || KERI || ABS || RMRoS || LROS (Lloyds register of shipping) || UL || RINA || DNV || GL || C-tick || ATEX
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Compliant with Exemptions
- Warranty:
- 18 months
- Rohs Exemption Information:
- Yes
- Fire Resistance:
- 650°C EN/IEC 60695-2-12 || 960°C UL 94
- Network And Machine Diagnosis Type:
- phase fault and earth fault trip counters || trip history information || trip context information || motor control command recording || running hours counter/operating time || waiting time after overload tripping || remaining operating time before ov
- Short-Circuit Withstand:
- 100 kA conforming to EN/IEC 60947-4-1
- Current State 0 Guaranteed:
- logic input 0...40 V <= 15 mA 25 ms
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Load Current:
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Operating Altitude:
- <= 6561.68 ft (2000 m) without derating
- Maximum Operating Frequency:
- 2 Hz
- Mercury Free:
- Yes
- Tightening Torque:
- control circuit 0.5-0.6 N.m flat 3 mm
- Country of Origin:
- China
- Permissible Power:
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Net Weight:
- 0.53 kg
- Product Name:
- TeSys T
- Depth:
- 122.5 mm
- Bus Type:
- Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, SUB-D 9 2 shielded twisted pairs, type A || Profibus DP polarised 2-wire RS485 1...125 9.6 kbit/s...12 Mbit/s, terminal block 2 shielded twisted pairs, type A
- Environmental Disclosure:
- ENVPEP060308EN_V2
- Range:
- TeSys
- Contacts Type And Composition:
- 1 NO + 1 NC fault signal || 3 NO
- Logic Input Number:
- 6
- Input Current:
- 3.1 mA 100 V || 7.5 mA 240 V
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Pvc Free:
- Yes
- Connections - Terminals:
- control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
- Supply Voltage Limits:
- 93.5-264 V AC
- Weight:
- 0.53 kg
- Measurement Current:
- 1.35-27 A
- Device Application:
- equipment monitoring and control
- Product Or Component Type:
- motor controller
- Overvoltage Category:
- III
- Ip Degree Of Protection:
- IP20
- Metering Type:
- average current Iavg || temperature || earth-fault current || phase current I1, I2, I3 RMS || imbalance current
- Ambient Air Temperature For Operation:
- -20-60°C
- Web Services:
- web server
- Connection Pitch:
- 5.08 mm
- Current State 1 Guaranteed:
- logic input 79...264 V >= 2 mA 25 ms
- Halogen Content Performance:
- Halogen free plastic parts product