Schneider Electric

Schneider Electric LX1G4SEHEA Control module,TeSys Giga,48-130V AC/DC,for LC1G400-500/4P advanced version

(No reviews yet) Write a Review
SKU:
LX1G4SEHEA
MPN:
LX1G4SEHEA
Condition:
New
Mercury Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Product Or Component Type:
contactor coil
Inrush Power In Va:
380-380 VA 120 V AC, 60 Hz
Hold-In Power Consumption In W:
5.3-5.3 W DC
Ambient Air Temperature For Operation:
-25-60°C
Circularity Profile:
ENVEOLI2105013
Device Short Name:
LX1G
Ambient Air Temperature For Storage:
-60-80°C
Pvc Free:
Yes
Operating Time:
20...35 ms opening || 40...55 ms closing
Depth:
93.0 mm
Product Compatibility:
LC1G400...500
Hold-In Power Consumption In Va:
10.1-10.1 VA 120 V AC, 60 Hz
Maximum Operating Rate:
600 cyc/mn 60°C
Poles Description:
4P
Standards:
EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
China Rohs Regulation:
X
Electromagnetic Compatibility:
EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity tes
Connections - Terminals:
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2
Operating Altitude:
9842.52 ft (3000 m) without derating || 5000 m with derating factor
Coil Technology:
built-in bidirectional peak limiting
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In W:
295.0 W DC
Country of Origin:
China
Range:
TeSys
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Mechanical Durability:
5 Mcycles
Eu Rohs Directive:
Compliant with Exemptions
Environmental Disclosure:
ENVPEP2105013
Control Circuit Voltage Limits:
operational 0.8...1.1 Uc 60°C) || drop-out 0...0.45 Uc 60°C)
[Uc] Control Circuit Voltage:
48...130 V AC/DC 50/60 Hz
Pollution Degree:
3 IEC 60947-1
Halogen Content Performance:
Halogen free plastic parts product
Range Compatibility:
TeSys G LX1G contactor coil
Quantity Per Set:
1
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP20 IEC 60529
$285.00

Description

It is a 48-130V AC/DC control module for 4 poles TeSys Giga 400-500 contactor (advanced version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit & PLC output control, pole status and diagnostic signaling circuits. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.
View AllClose