Schneider Electric

Schneider Electric METSEEM3502 PowerLogic EM3500 DIN rail meter - pulse - current transformer

(No reviews yet) Write a Review
SKU:
METSEEM3502
MPN:
METSEEM3502
Condition:
New
Mercury Free:
Yes
Output Voltage:
30 V AC/DC
Device Application:
partial meter || sub billing
Relative Humidity:
0-95 %
Analogue Input Type:
split core current transducer 0.333 V or 1 V
9 Mm Pitches:
12
Depth:
59 mm
Information Displayed:
status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
Technology Type:
electronic
Local Signaling:
Red LED threshold reached || Green flashing LED output signal
China Rohs Regulation:
X
Standards:
UL 508 || CSA C22.2 No 14-05 || IEC 61010-1
Accuracy Class:
class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20
[Ue] Rated Operational Voltage:
90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
Data Recording:
energy consumption logs
Country of Origin:
United States
Product Certifications:
CE conforming to IEC 61010 || cULus conforming to UL 508
Number Of Outputs:
2 pulse || 1 alarm output
Ride-Through Time:
100 ms 120 V AC
Range:
PowerLogic
Mounting Mode:
clip-on || by screws
Eu Rohs Directive:
Compliant with Exemptions
Mounting Support:
DIN rail
Poles Description:
3P + N
Power Consumption In W:
3 W 300-300 V
Ambient Air Temperature For Operation:
-30-70°C
Function Available:
fixed or rolling block
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Height:
91 mm
Rated Voltage:
90-347 V
Display Digits:
5
Product Or Component Type:
energy meter
Device Short Name:
EM3502
Power Consumption In Va:
5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
Type Of Measurement:
active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
Communication Port Protocol:
-
Product Name:
PowerLogic EM3500
Rohs Exemption Information:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Display Type:
Backlit LCD
Ambient Air Temperature For Storage:
-40-85°C
Network Frequency:
60 Hz || 50 Hz
Communication Service:
total cumulated active energy || total cumulated energy
Metering Type:
demand power P, Q, S || peak demand power PM, QM, SM || current I1, I2, I3, Iavg || voltage U21, U32, U13, V1, V2, V3
Measurement Accuracy:
power +/- 0.2 % || energy +/- 0.2 %
Tamperproof Of Settings:
protected by access code
Color:
dark grey
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
$1,399.45

Description

The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. 2 pulse outputs to communicate active and reactive energy, and 1 normaly closed contact for alarm. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.