Schneider Electric

Schneider Electric METSEEM3550 PowerLogic EM3500 DIN rail meter - Modbus 2 quadrant - current transformer

(No reviews yet) Write a Review
SKU:
METSEEM3550
MPN:
METSEEM3550
Condition:
New
Local Signaling:
Red LED threshold reached || Green flashing LED output signal
9 Mm Pitches:
12
Number Of Outputs:
1 alarm output || 1 pulse
Technology Type:
electronic
Display Type:
Backlit LCD
Communication Port Protocol:
Modbus RTU 1200…38400 bps - 2-wire
Communication Port Support:
screw terminal block RS485
Mounting Mode:
clip-on || by screws
Standards:
UL 508 || IEC 61010-1 || CSA C22.2 No 14-05
Accuracy Class:
class 0.2S power IEC 62053-22 || class 0.2S energy IEC 62053-22 || class 0.2S power ANSI C12.20 || class 0.2S energy ANSI C12.20
Ambient Air Temperature For Storage:
-40-85°C
Communication Service:
total cumulated energy || total cumulated active energy
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
X
Measurement Current:
5-32000 A
Device Application:
sub billing || partial meter
Metering Type:
voltage U21, U32, U13, V1, V2, V3 || peak demand power PM, QM, SM || demand power P, Q, S || current I1, I2, I3, Iavg
Type Of Measurement:
active and reactive power total || active and reactive power per phase || apparent power total || apparent power per phase || power factor total || power factor per phase || peak demand power || current || voltage || frequency
Product Certifications:
CE conforming to IEC 61010 || cULus conforming to UL 508
[Ue] Rated Operational Voltage:
90...347 V AC 50/60 Hz between phase and neutral UL || 156...600 V AC 50/60 Hz between phases UL || 90...300 V AC 50/60 Hz between phase and neutral CE || 125...300 V DC
Analogue Input Type:
split core current transducer 0.333 V or 1 V
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Measurement Accuracy:
power +/- 0.2 % || energy +/- 0.2 %
Depth:
59 mm
Power Consumption In W:
3 W 300-300 V
Function Available:
fixed or rolling block || external synchronisation to communication
Ambient Air Temperature For Operation:
-30-70°C
Display Digits:
5
Country of Origin:
Mexico
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Product Or Component Type:
energy meter
Ride-Through Time:
100 ms 120 V AC
Relative Humidity:
0-95 %
Poles Description:
3P + N
Power Consumption In Va:
5-5 VA 347 V AC between phase and neutral) || 5-5 VA 600 V AC between phases)
Information Displayed:
status and alert || communication with system || input/output status || error || Tx activity || Rx activity || instant power per usage
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Name:
PowerLogic EM3500
Range:
PowerLogic
Device Short Name:
EM3550
Data Recording:
energy consumption logs
Tamperproof Of Settings:
protected by access code
Color:
dark grey
Mounting Support:
DIN rail
$1,047.28

Description

The EM3500 series offer a three-phases DIN rail-mounted energy meters fitted for accurate cost allocation and sub-metering. EM35xx models are designed for use with Low Votage Current Transducers 1/3Volt or 1Volt output. Current input from 5A to 32000A, according to the LVCT configuration in the HMI, ANSI C12.20 0.2% accuracy, IEC 62053-22 class 0.2S. Modbus, pulse output, and phase alarms are all provided to suit a wide variety of applications. Suitable for a 230V AC network, with a supply voltage range of 90V AC to 300V AC at 50Hz or 60Hz. Compliant with UL508, CSA 22.2 number 14-05 and EN 61010-1. Product dimensions are as follows: width 107 mm, depth 59 mm, height 91 mm.