Schneider Electric

Schneider Electric METSEEM4236A18 Enercept Meter, class 0.2S, Modbus/BACnet RS485, Rogowski 18", ANSI wire code

(No reviews yet) Write a Review
SKU:
METSEEM4236A18
MPN:
METSEEM4236A18
Condition:
New
Mounting Mode:
by screws || clip-on || by hook
Measurement Voltage:
90-90 V AC 45...65 Hz minimum per phase || 480-480 V AC 45...65 Hz between phases || 300-300 V AC 45...65 Hz between phase and neutral
Communication Port Protocol:
Modbus RTU 9600 bauds...115200 bauds (automatic detection) || BACnet MS/TP 9600 bauds...115200 bauds (automatic detection)
Mercury Free:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Wire Stripping Length:
6 mm
Device Application:
power monitoring
Mounting Support:
enclosure || DIN rail
Network Frequency:
50 Hz || 60 Hz
Reach Free Of Svhc:
Yes
Communication Of Data:
remote control orders || total energy || net energy
Product Name:
PowerLogic EM4200
Metering Type:
active, reactive, apparent energy (signed, four quadrant) || apparent power S, S1, S2, S3 || demand power P, Q, S || active power P, P1, P2, P3 || reactive power Q, Q1, Q2, Q3 || power factor || average current Iavg || peak demand power PM, QM, SM ||
Provided Equipment:
bracket for support || hook || Rogowski coil 3 18 in || fuse
Measurement Current:
50-5000 A
Connections - Terminals:
input/output plug-in connector bottom) 0.2-1.5 mm² || current transformer plug-in connector bottom) 0.2-1.5 mm² || communication plug-in connector bottom) 0.2-1.5 mm²
Relative Humidity:
0-95 %
Product Certifications:
CE conforming to EN 61010-1 || cULus conforming to UL 61010-1 || BTL || IEC
Depth:
35.81 mm
Operating Altitude:
< 9842.52 ft (3000 m)
Local Signaling:
status LED green and red) || line fault 3 LED green, orange and red) || dial pointer indication LED Yellow) || RX/TX 2 LED green, orange and red)
Display Type:
Without Display
Electromagnetic Compatibility:
conducted and radiated emissions conforming to FCC Part 15 class A || conducted and radiated emissions conforming to EN 61000-6-4 || conducted and radiated emissions conforming to EN 61326 + A1 || immunity to conducted disturbances conforming to EN 6
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Pollution Degree:
2
Analogue Input Type:
Rogowski coil 0.333 V (impedance 33 kOhm) || voltage (impedance 2.5 MOhm)single phase || voltage (impedance 5 MOhm)phase to phase
Type Of Cable:
ANSI cable
Function Available:
external synchronisation to communication || fixed or rolling block
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Device Short Name:
Enercept
Ambient Air Temperature For Storage:
-40-85°C
Standards:
EN 61010-1 || UL 61010-1 || CAN/CSA C22.2 No. 61010-1-12
Frequency Measurement Range:
45-65 Hz
Number Of Inputs:
0
Measurement Accuracy:
0.01
Rohs Exemption Information:
Yes
Number Of Outputs:
0
Country of Origin:
United States
Product Or Component Type:
energy meter
Range:
PowerLogic
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Ambient Air Temperature For Operation:
-15-60°C
Measurement Category:
category III 277-277 V || category III 300-300 V
Eu Rohs Directive:
Compliant with Exemptions
Accuracy Class:
class 1 ANSI C12.1 || class 1S IEC 62053-22
$2,167.16

Description

The PowerLogic EM4200 Series Enercept power and energy meter is a unique compact retrofit solution for measuring energy data. This bundle ships with 3, 18 inch Rogowski current transformers rated up to 5,000 A. Accuracy calibrated at 1%. ANSI version, fuse packs factory mounted. Designed for simplicity, the EM4200 has flexibility of a wide range of Current Transducers to match most applications from 50-5000A. This billing-rated, four-quadrant meter offers BACnet and Modbus communication protocols and supply power options from 90-480VAC. ANSI C12.1 rated and UL 61010-1.