Schneider Electric

Schneider Electric METSEION7400 Power quality meter, PowerLogic ION7400, Standard, integrated display, 512 MB, 256 s/c, THD, RVC

(No reviews yet) Write a Review
SKU:
METSEION7400
MPN:
METSEION7400
Condition:
New
Operating Altitude:
9842.52 ft (3000 m)
Memory Capacity:
512 MB
Variant:
standard
Network Frequency:
50 Hz || 60 Hz
Display Type:
colour TFT LCD
Ip Degree Of Protection:
IP54 front: conforming to IEC 60529 || IP30 body: conforming to IEC 60529
Web Services:
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Communication Service:
DHCP || RSTP support || NTP time synchronization || SMTP e-mail notification || PTP time synchronization
Communication Port Protocol:
Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004 || Ansi C12.19 || DLMS
Measurement Current:
50-10000 mA
Communication Port Support:
ETHERNET || screw terminal block RS485 || optical probe fiber optic || mini B USB USB
Range:
PowerLogic
Cybersecurity:
Syslog protocol support || robust security logs || enable/disable communication ports || password protection || port hardening
Poles Description:
1P + N || 3P || 3P + N
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Circularity Profile:
ENVEOLI1512006EN
Power Consumption In Va:
18 VA 415 V AC
Frequency Measurement Range:
42-69 Hz
Type Of Measurement:
current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms || active and reactive energy
Accuracy Class:
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 curre
Depth:
78.5 mm
Ambient Air Temperature For Operation:
-25-70°C
Line Rated Current:
10 A || 5 A || 1 A
Sampling Rate:
256 samples/cycle
Type Of Installation:
indoor installation
China Rohs Regulation:
X
[Us] Rated Supply Voltage:
90...415 V AC 45...65 Hz +/- 10 % || 110...415 V DC +/- 10 %
Ambient Air Temperature For Storage:
-40-85°C
Product Or Component Type:
power meter
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
Environmental Disclosure:
ENVPEP1512006EN
Product Certifications:
CE || cULus || N998
Power Quality Analysis:
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (lo
Standards:
IEC 62053-22 || IEC 62052-11 || IEC 62053-24 || IEC 61557-12 || IEC 61326-1 || IEEE 1588 || IEC 62586
Electromagnetic Compatibility:
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test confor
Device Application:
revenue billing || WAGES metering || data aggregation || power monitoring
Relative Humidity:
5-95 %
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Net Weight:
706 g
Device Short Name:
ION7400
Display Resolution:
320 x 240 pixels QVGA
Sustainable Offer Status:
Green Premium product
Communication Network Type:
IPv6 (internet protocol)
Number Of Outputs:
1 pulse
Eu Rohs Directive:
Compliant with Exemptions
Number Of Inputs:
3 digital 30 V AC || 3 digital 60 V DC
$9,800.72

Description

PowerLogic ION7400 utility feeder power meters combine capabilities not typically available in compact meters. They offers a hight flexibility and usability, along with accurate 3-phase energy and power measurements with data logging. Use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 16 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. Panel mounting (1/4 DIN) with integrated display.
View AllClose