Schneider Electric

Schneider Electric METSEION7403 Power quality meter, PowerLogic ION7400, Standard, transducer, 512 MB, 256 s/c

(No reviews yet) Write a Review
SKU:
METSEION7403
MPN:
METSEION7403
Condition:
New
Frequency Measurement Range:
42-69 Hz
Cybersecurity:
enable/disable communication ports || port hardening || Syslog protocol support || password protection || robust security logs
Weight:
528 g
Range:
PowerLogic
Environmental Disclosure:
ENVPEP1512006EN
Device Application:
revenue billing || data aggregation || power monitoring || WAGES metering
Product Or Component Type:
power meter
Type Of Measurement:
current || voltage || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms || active and reactive energy
Data Recording:
time stamping || trending/forecasting || waveform logs || sequence of event recording || min/max of instantaneous values || harmonics logs || data logs || sag and swell logs || GPS synchronisation || event logs || alarm logs || 50 data recorders
Product Name:
PowerLogic ION7400
Ip Degree Of Protection:
IP30 conforming to IEC 60529
Power Quality Analysis:
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class S power quality measurement || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (lo
China Rohs Regulation:
X
Eu Rohs Directive:
Compliant with Exemptions
Variant:
standard
Ambient Air Temperature For Storage:
-40-85°C
Accuracy Class:
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 curre
Operating Altitude:
9842.52 ft (3000 m)
Mounting Mode:
clip-on
Device Short Name:
ION7403
Measurement Current:
50-10000 mA
Rohs Exemption Information:
Yes
Poles Description:
3P + N || 3P || 1P + N
Mounting Support:
DIN rail
Type Of Installation:
indoor installation
Net Weight:
528 g
Memory Capacity:
512 MB
Number Of Outputs:
1 pulse
Information Displayed:
voltage || current || frequency || power || energy consumption || harmonic distortion
Measurement Voltage:
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Number Of Inputs:
3 digital 30 V AC || 3 digital 60 V DC
Installation Category:
III
Line Rated Current:
1 A || 5 A || 10 A
Depth:
90.8 mm
Standards:
IEC 62052-11 || IEC 61557-12 || IEC 62053-22 || IEC 62053-24 || IEC 61326-1 || IEEE 1588 || IEC 62586
Communication Port Support:
ETHERNET || screw terminal block RS485 || mini B USB USB
Power Consumption In Va:
18 VA 415 V AC
[Us] Rated Supply Voltage:
90...415 V AC 45...65 Hz +/- 10 % || 110...415 V DC +/- 10 %
Circularity Profile:
ENVEOLI1512006EN
Measurement Accuracy:
current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Communication Network Type:
IPv6 (internet protocol)
Sampling Rate:
256 samples/cycle
Product Certifications:
CE || cULus || N998
Web Services:
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Country of Origin:
Mexico
$8,922.06

Description

PowerLogic ION7400 utility feeder power meters combine capabilities not typically available in compact meters. They offers a hight flexibility and usability, along with accurate 3-phase energy and power measurements with data logging. Use Power Monitoring Expert software for data analysis or share operation data with SCADA systems through multiple communication channels and protocols. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 16 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. DIN rail mounting (no display).
View AllClose