Schneider Electric

Schneider Electric METSEION7413A Power quality meter, PowerLogic ION7400, Advanced, transducer, 512 MB, 512 s/c

(No reviews yet) Write a Review
SKU:
METSEION7413A
MPN:
METSEION7413A
Condition:
New
Measurement Voltage:
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Product Name:
PowerLogic ION7400
Number Of Outputs:
1 pulse
Sampling Rate:
512 samples/cycle
Circularity Profile:
ENVEOLI1512006EN
Ambient Air Temperature For Storage:
-40-85°C
Environmental Disclosure:
ENVPEP1512006EN
Weight:
528 g
Relative Humidity:
5-95 %
Poles Description:
1P + N || 3P || 3P + N
Isolation Voltage:
III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Depth:
90.8 mm
Frequency Measurement Range:
42-69 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
revenue billing || WAGES metering || data aggregation || power monitoring
Product Certifications:
CE || cULus || N998
Data Recording:
sequence of event recording || trending/forecasting || harmonics logs || time stamping || GPS synchronisation || waveform logs || min/max of instantaneous values || sag and swell logs || data logs || event logs || alarm logs || 64 data recorders
Electromagnetic Compatibility:
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test confor
Power Consumption In W:
17 W
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Height:
90.5 mm
Display Type:
Without Display
Communication Port Protocol:
Modbus RTU 115 kbauds - 2-wire || ION 115 kbauds - 2-wire || DNP3 || IEC 61850 || Modbus TCP/IP || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s || RSTP 801.1d 2004 || DLMS
Memory Capacity:
512 MB
Standards:
IEC 61326-1 || IEC 62053-22 || IEC 62053-24 || IEC 62052-11 || IEC 61557-12 || IEEE 1588 || IEC 62586
Accuracy Class:
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 curre
Line Rated Current:
10 A || 1 A || 5 A
Mounting Support:
DIN rail
Web Services:
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Installation Category:
III
[Us] Rated Supply Voltage:
20...60 V DC +/- 10 %
Information Displayed:
voltage || current || frequency || power || energy consumption || harmonic distortion
Network Frequency:
50 Hz || 60 Hz
Measurement Current:
50-10000 mA
Measurement Accuracy:
current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
Type Of Measurement:
current || voltage total || frequency total || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms || active and rea
Sustainable Offer Status:
Green Premium product
Operating Altitude:
9842.52 ft (3000 m)
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
Number Of Inputs:
3 digital 30 V AC || 3 digital 60 V DC
Cybersecurity:
enable/disable communication ports || robust security logs || port hardening || password protection || Syslog protocol support
Ip Degree Of Protection:
IP30 conforming to IEC 60529
Net Weight:
528 g
Ambient Air Temperature For Operation:
-25-70°C
Communication Port Support:
ETHERNET || screw terminal block RS485 || mini B USB USB
Mounting Mode:
clip-on
Power Quality Analysis:
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || IEC 61000-4-30 class A power quality measurement || up to the 63rd harmonic || IEC 61000-4-15 harmonic distortion || EN 50160 2010 waveform capture || IEC 61000-4-30 class A volta
$10,442.08