Schneider Electric

Schneider Electric METSEION93130 PowerLogicâ„¢ ION9000 meter, LVDC, DIN mount, Low Voltage input current, no display, HW kit

(No reviews yet) Write a Review
SKU:
METSEION93130
MPN:
METSEION93130
Condition:
New
Range:
PowerLogic
Mercury Free:
Yes
Accuracy Class:
class 0.1S active energy IEC 62053-22 || class 0.1 active energy IEC 61557-12 || class 0.1 active energy ANSI C12.20 || class 0.5S reactive energy IEC 62053-24 || class 0.1 current IEC 61557-12 || class 0.1 voltage IEC 61557-12 || class 0.1 active po
Electrical Insulation Class:
class III EN/IEC 62052-11
Web Services:
viewing of captured waveform || web page || pass/fail report for IEEE 519 || pass/fail report for EN 50160 || ITIC (CBEMA) curve || SEMI curve || NEMA motor derating curve || alarm notification by e-mail || TLS 1.2 || push historical data via mail
Environmental Disclosure:
ENVPEP1801009EN
Ambient Air Temperature For Operation:
-25-70°C
Product Or Component Type:
energy and power quality meter
Number Of Inputs:
8 digital 30 V AC/60 V DC
Communication Gateway:
Ethernet/serial
Relative Humidity:
5-95 %
Communication Port Support:
2 RS485 removable screw terminal block
Electromagnetic Compatibility:
EMC immunity conforming to IEC 62052-11 || EMC immunity conforming to IEC 61326-1 || EMC immunity conforming to IEC 61000-6-5 || electrostatic discharge immunity test conforming to IEC 61000-4-2 || immunity to radiated fields conforming to IEC 61000-
Net Weight:
1.5 kg
[Us] Rated Supply Voltage:
20...60 V DC +/- 10 %
Sampling Rate:
1024 samples/cycle
Depth:
135.3 mm
Device Application:
power monitoring || WAGES metering || Net metering || medium voltage || high voltage
Circularity Profile:
ENVEOLI1801009EN
Ambient Air Temperature For Storage:
-40-85°C
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Quality Labels:
ISO 9001 || ISO 14000
Country of Origin:
Mexico
Data Recording:
time stamping || min/max of instantaneous values || user-definable data logs || continuous logging or snapshot || trending/forecasting || event logs || alarm logs || configuration change || power outage || user login/logout || data logs || GPS synchr
Communication Port Protocol:
Modbus RTU 2400...115200 bps - 2-wire || ION 2400...115200 bps - 2-wire || DNP3 2400...115200 bps - 2-wire || Modbus TCP 10/100 Mbit/s || ION TCP 10/100 Mbit/s || DNP3 TCP 10/100 Mbit/s || IEC 61850 || Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s
Cybersecurity:
Syslog protocol support || robust security logs || port hardening || enable/disable communication ports || hardware metrology lock
Mounting Support:
DIN rail
Eu Rohs Directive:
Compliant with Exemptions
Measurement Voltage:
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Isolation Voltage:
III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Ethernet Service:
DHCP client || Device Profile Web Services (DPWS) || Rapid Scanning Tree Protocol (RSTP) || FTP/HTTP/HTTPS
Display Type:
Without Display
Metering Type:
demand current I1, I2, I3, I4, I5 || peak demand currents || demand power P, Q, S || peak demand power PM, QM, SM || calculated active and reactive energy (+/- W.h, +/- VAR.h)
China Rohs Regulation:
X
Ip Degree Of Protection:
IP65 front: || IP30 rear:
Port Ethernet:
10/100BASE-TX 2 RJ45
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Degree Of Protection:
UL type 12, front
Time Synchronisation Protocol:
GPS || IRIG-B || NTP || SNTP || PTP
Communication Service:
compliant reports || power quality summary || energy report || EcoStruxure Power Events Analysis || SMTP e-mail notification || SNMP
Ride-Through Time:
500 ms 60 V DC typical
Width:
160 mm
Frequency Measurement Range:
20-450 Hz
Maximum Power Consumption In Va:
38 W 20...60 V DC
Type Of Measurement:
voltage sags and swells || current sags and swells || voltage || current || frequency || active and reactive power total || apparent power total || active and reactive power per phase || apparent power per phase || power factor total || power factor
Standards:
ANSI C12.20 || ANSI C37.90.1 || IEC 61000-4-15 || IEC 61000-4-30 || IEC 61010-1 || IEC 61326-1 || IEC 61557-12 || IEC 61850 || IEC 62052-11 || IEC 62052-31 || IEC 62053-22 || IEC 62053-23 || IEC 62053-24 || IEC 62586 || UL 61010-1
$21,655.80

Description

The PowerLogic ION9000 is your 24/7 power quality expert, providing information, not just data. A comprehensive, industry-leading Power Quality Instrument (PQI-A) certified to IEC 62586-1/-2 ensures reliable, precision performance that is perfect for both supply and demand side applications. Third-party lab verified accuracy to Class 0.1S (ANSI C12.20, IEC 62053-22). Highly customizable and modular, ION technology programmability and field installable option modules can satisfy any solution, protecting your investment now and into the future. Providing power quality analysis according to both EN 50160 and IEEE 519, and patented Disturbance Direction Detection, you become a PQ expert and will be able to respond rapidly to system events. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol, ability to enable/disable communication ports, and 50 user configurable accounts. With 2 GB of memory to support 50 data logs, 50+ user-definable alarms, disturbance and transient waveforms. 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 8 digital inputs, 4 digital outputs and 2 relay outputs, plus the ability to add up to 4 option modules. Option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Ability to capture power quality events as short as 20 µs and record both waveforms and 1/2-cycle RMS concurrently on any event. Voltage inputs of 100 to 690 V between phases; Current inputs with low voltage transducer; Frequency of 20-450 Hz. Low voltage control power range of 20 to 60 VDC. DIN rail mounting or panel mounting (with back to back adapter) transducer, plus 2 display options, further enhance the flexibility and adaptability of the ION9000.
View AllClose