Schneider Electric

Schneider Electric METSEPM5330 power meter PowerLogic PM5330, modbus, up to 31st Harmonic, 256KB 2DI/2DO 35 alarms

(No reviews yet) Write a Review
SKU:
METSEPM5330
MPN:
METSEPM5330
Condition:
New
Sampling Rate:
64 samples/cycle
Rohs Exemption Information:
Yes
Information Displayed:
tariff 4)
Maximum Power Consumption In Va:
11 VA 415 V
Eu Rohs Directive:
Compliant with Exemptions
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance <= 0.3 mOhm)
Poles Description:
3P + N || 3P || 1P + N
Device Application:
power monitoring || multi-tariff
Accuracy Class:
class 0.5S active energy IEC 62053-22
Ambient Air Temperature For Storage:
-40-85°C
Power Quality Analysis:
up to the 31st harmonic
Country of Origin:
India
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Number Of Inputs:
2 digital
Memory Capacity:
256 kB
Product Name:
PowerLogic PM5000
Mercury Free:
Yes
Height:
96 mm
Line Rated Current:
1 A || 5 A
Measurement Current:
5-8500 mA
Measurement Voltage:
35-760 V AC 45...65 Hz between phases || 20-400 V AC 45...65 Hz between phase and neutral
Ambient Air Temperature For Operation:
-25-70°C meter
Data Recording:
maintenance logs || time stamping || alarm logs || data logs || min/max of instantaneous values || event logs
Measurement Accuracy:
active energy +/- 0.5 % || reactive energy +/- 2 % || active power +/- 0.5 % || apparent power +/- 0.5 % || frequency +/- 0.05 % || power factor +/- 0.5 || current +/- 0.5 % || voltage +/- 0.5 % || apparent energy +/- 0.5 % || reactive power +/- 2 %
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Circularity Profile:
ENVEOLI1305025
Sustainable Offer Status:
Green Premium product
Pollution Degree:
2
Number Of Outputs:
2 relay || 2 digital
Environmental Disclosure:
ENVPEP1305025
Relative Humidity:
5-95 % 50-50°C non-condensing
Communication Port Protocol:
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS
Depth:
72 mm
[Us] Rated Supply Voltage:
90...450 V AC 45...65 Hz || 100...300 V DC
Operating Altitude:
6561.68 ft (2000 m) CAT III || 9842.52 ft (3000 m) CAT II
Electromagnetic Compatibility:
conducted and radiated emissions class B conforming to EN 55022 || immunity to conducted disturbances - test level: 150 kHz...80 MHz level 4 conforming to IEC 61000-4-6 || electrical fast transient/burst immunity test level 3 conforming to IEC 61000-
Frequency Measurement Range:
45-65 Hz
Network Frequency:
50 Hz || 60 Hz
Communication Port Support:
RS485
Mounting Mode:
flush-mounted
China Rohs Regulation:
X
Device Short Name:
PM5330
Product Or Component Type:
power meter
Display Type:
monochrome graphic LCD
Type Of Measurement:
current || voltage || frequency || power factor || energy || active and reactive power
Display Resolution:
128 x 128 pixels
Connections - Terminals:
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || input/output circuit screw terminal block6 || relay output screw terminal block4 || Ethernet network RJ45 connector
$1,819.61

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has two digital inputs or digital outputs, configurable, and dual relay outputs. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).