Schneider Electric

Schneider Electric METSEPM5562 power meter PowerLogic PM5562, 2 ethernet, up to 63th Harmonic, 1,1MB 4DI/2DO 52 alarms, RMICAN lock

(No reviews yet) Write a Review
SKU:
METSEPM5562
MPN:
METSEPM5562
Condition:
New
Data Recording:
event logs || maintenance logs || min/max of instantaneous values || data logs || alarm logs || time stamping
Net Weight:
450 g
China Rohs Regulation:
X
Electromagnetic Compatibility:
limits for harmonic current emissions class A conforming to IEC 61000-3-2 || conducted RF disturbances level 3 conforming to IEC 61000-4-6 || magnetic field at power frequency level 4 conforming to IEC 61000-4-8 || conducted and radiated emissions cl
Width:
96 mm
Product Name:
PowerLogic PM5000
Depth:
72 mm
Device Application:
gateway || WAGES metering || power monitoring || multi-tariff
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1310016EN
Circularity Profile:
ENVEOLI1310016EN
Web Services:
alarm notification by e-mail || diagnostic via predefined web pages || web server || real time viewing of data
Ambient Air Temperature For Operation:
-25-70°C
Measurement Voltage:
20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases
Rohs Exemption Information:
Yes
Weight:
450 g
Mounting Mode:
flush-mounted
Line Rated Current:
1 A || 5 A
Network Frequency:
60 Hz || 50 Hz
Communication Port Support:
RS485 || ETHERNET
Metering Type:
measured neutral current || calculated ground current
Connections - Terminals:
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Et
Range:
PowerLogic
Display Type:
Backlit LCD
Number Of Outputs:
2 digital
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Toxic Heavy Metal Free:
Yes
Ride-Through Time:
35 ms 120 V AC typical || 129 ms 230 V AC typical
Poles Description:
3P + N || 3P || 1P + N
Device Short Name:
PM5562
California Proposition 65:
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Standards:
EN 50470-3 || IEC 61557-12:2015 || IEC 62053-22:2020 || IEC 62053-24 || IEC 60529 || EN 50470-1 || UL 61010-1 || IEC 62053-23:2020 || IEC 62052-11:2020 || IEC 62052-31:2015
Type Of Measurement:
current || voltage || frequency || power factor || energy || active and reactive power
Pollution Degree:
2
Sampling Rate:
128 samples/cycle
Measurement Accuracy:
apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 %
Communication Port Protocol:
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP
Maximum Power Consumption In Va:
10 VA 480 V
Communication Gateway:
Ethernet/serial
Mounting Support:
framework
Operating Altitude:
9842.52 ft (3000 m)
Frequency Measurement Range:
45-65 Hz
Power Quality Analysis:
up to the 63rd harmonic
Product Or Component Type:
power meter
Relative Humidity:
5-95 % 50-50°C non-condensing
Eu Rohs Directive:
Compliant
Ip Degree Of Protection:
IP54 display: conforming to IEC 60529 || IP30 rear: conforming to IEC 60529
$5,361.52

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display and RMICAN approved, with hardware lock. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).
View AllClose