Connections - Terminals:
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Et
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance <= 0.3 mOhm)
Number Of Outputs:
2 digital
Measurement Accuracy:
apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %
Mounting Mode:
clip-on
Mounting Support:
DIN rail
Data Recording:
time stamping || data logs || maintenance logs || event logs || alarm logs || min/max of instantaneous values
Communication Port Protocol:
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet
Frequency Measurement Range:
45-65 Hz
Display Resolution:
128 x 128 pixels
Metering Type:
measured neutral current || calculated ground current
Accuracy Class:
class 0.2S active energy IEC 62053-22
China Rohs Regulation:
X
Environmental Disclosure:
ENVPEP1412028EN
Reach Free Of Svhc:
Yes
Memory Capacity:
1.1 MB
Number Of Inputs:
4 digital
Information Displayed:
tariff 8)
Ip Degree Of Protection:
IP54 display: conforming to IEC 60529 || IP30 rear: conforming to IEC 60529
Sustainable Offer Status:
Green Premium product
Measurement Voltage:
20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases
Range:
PowerLogic
Electromagnetic Compatibility:
limits for harmonic current emissions class A conforming to IEC 61000-3-2 || conducted RF disturbances level 3 conforming to IEC 61000-4-6 || magnetic field at power frequency level 4 conforming to IEC 61000-4-8 || conducted and radiated emissions cl
Width:
96 mm
Ambient Air Temperature For Storage:
-40-85°C
Communication Gateway:
Ethernet/serial
Country of Origin:
Mexico
Ambient Air Temperature For Operation:
-25-70°C
Web Services:
diagnostic via predefined web pages || real time viewing of data || web server || alarm notification by e-mail
Network Frequency:
50 Hz || 60 Hz
Type Of Measurement:
current || voltage || frequency || power factor || energy || active and reactive power
Net Weight:
450 g
Product Or Component Type:
power meter
Poles Description:
1P + N || 3P || 3P + N
Power Quality Analysis:
up to the 63rd harmonic
Eu Rohs Directive:
Compliant
Standards:
EN 50470-3 || EN 50470-1 || IEC 62053-22:2020 || IEC 60529 || UL 61010-1 || IEC 62053-24 || IEC 61557-12:2015 || ANSI C12.20 || IEC 62053-23:2020 || IEC 62052-11:2020 || IEC 62052-31:2015
Toxic Heavy Metal Free:
Yes
Ethernet Service:
SNTP client || SNMP-Traps
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pollution Degree:
2
Measurement Current:
50-10000 mA
[Us] Rated Supply Voltage:
100...300 V DC || 90...528 V AC 45...65 Hz
Communication Port Support:
RS485 || ETHERNET
Mercury Free:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Device Short Name:
PM5563
$4,316.40

Description

This device is a DIN-mount energy meter with an additional 96mm by 96mm backlit LCD remote display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).