Schneider Electric

Schneider Electric METSEPM5580 power meter PowerLogic PM5580, 2 ethernet, up to 63th Harmonic, 1,1MB, 24VDC, 4DI/2DO 52 alarms

(No reviews yet) Write a Review
SKU:
METSEPM5580
MPN:
METSEPM5580
Condition:
New
Type Of Measurement:
current || voltage || frequency || power factor || energy || active and reactive power
Display Resolution:
128 x 128 pixels
Power Quality Analysis:
up to the 63rd harmonic
Sustainable Offer Status:
Green Premium product
Weight:
450 g
Mounting Support:
framework
Device Application:
gateway || WAGES metering || power monitoring || multi-tariff
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
X
Frequency Measurement Range:
45-65 Hz
Pollution Degree:
2
Network Frequency:
60 Hz || 50 Hz
Line Rated Current:
1 A || 5 A
Communication Port Support:
RS485 || ETHERNET
Measurement Accuracy:
apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %
Number Of Outputs:
2 digital
Ethernet Service:
SNTP client || SNMP-Traps
Circularity Profile:
ENVEOLI1909005
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance <= 0.3 mOhm)
Measurement Voltage:
20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases
[Us] Rated Supply Voltage:
24 V DC
Relative Humidity:
5-95 % 50-50°C non-condensing
Operating Altitude:
<= 9842.52 ft (3000 m)
Environmental Disclosure:
ENVPEP1909005
Product Or Component Type:
power meter
Communication Gateway:
Ethernet/serial
Sampling Rate:
128 samples/cycle
Net Weight:
450 g
Communication Port Protocol:
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet
Depth:
72 mm
Information Displayed:
tariff 8)
Poles Description:
3P + N || 3P || 1P + N
Ambient Air Temperature For Storage:
-40-85°C
Measurement Current:
50-10000 mA
Data Recording:
event logs || maintenance logs || min/max of instantaneous values || data logs || alarm logs || time stamping
Electromagnetic Compatibility:
limits for harmonic current emissions class A conforming to IEC 61000-3-2 || conducted RF disturbances level 3 conforming to IEC 61000-4-6 || magnetic field at power frequency level 4 conforming to IEC 61000-4-8 || conducted and radiated emissions cl
Height:
96 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Metering Type:
measured neutral current || calculated ground current
Rohs Exemption Information:
Yes
Memory Capacity:
1.1 MB
Ambient Air Temperature For Operation:
-25-70°C
Device Short Name:
PM5580
Connections - Terminals:
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Et
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Country of Origin:
India
Display Type:
monochrome graphic LCD
Ip Degree Of Protection:
IP54 display: conforming to IEC 60529 || IP30 rear: conforming to IEC 60529
$3,721.10

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current. The meter will function in a DC network and accepts a supply voltage of 24 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).