Schneider Electric

Schneider Electric METSEPM5650 power meter PowerLogic PM5650, 2 ethernet, up to 63th Harmonic, 1,1MB, waveform, 4DI/2DO 52 alarms

(No reviews yet) Write a Review
SKU:
METSEPM5650
MPN:
METSEPM5650
Condition:
New
Communication Port Support:
RS485 || ETHERNET
Mounting Support:
framework
Pollution Degree:
2
Product Name:
PowerLogic PM5000
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Or Component Type:
power meter
Information Displayed:
tariff 8)
Display Resolution:
128 x 128 pixels
Connections - Terminals:
voltage circuit screw terminal block4 || control circuit screw terminal block2 || current transformer screw terminal block6 || RS485 link screw terminal block4 || digital input screw terminal block8 || digital output screw terminal block4 || Et
Measurement Accuracy:
apparent power +/- 0.5 % || frequency +/- 0.05 % || active energy +/- 0.2 % || reactive energy +/- 1 % || active power +/- 0.2 % || voltage +/- 0.1 % || power factor +/- 0.005 || current +/- 0.15 % || reactive power +/- 1 %
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Ethernet Service:
SNTP client || SNMP-Traps
Measurement Current:
50-10000 mA
Rohs Exemption Information:
Yes
Operating Altitude:
<= 9842.52 ft (3000 m)
Device Short Name:
PM5650
Communication Port Protocol:
Modbus RTU and ASCII 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires 2500 V || JBUS || Modbus TCP/IP 10/100 Mbit/s 2500 V || Ethernet Modbus TCP/IP daisy chain || BACnet IP || DNP3 over ethernet
Measurement Voltage:
20-400 V AC 45...65 Hz between phase and neutral || 20-828 V AC 45...65 Hz between phases
Depth:
72 mm
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance <= 0.3 mOhm)
Standards:
EN 50470-3 || IEC 61557-12:2015 || IEC 62053-22:2020 || IEC 62053-24 || IEC 60529 || EN 50470-1 || UL 61010-1 || IEC 62053-23:2020 || IEC 62052-11:2020 || IEC 62052-31:2015
Web Services:
alarm notification by e-mail || web server || diagnostic via predefined web pages || real time viewing of data
Metering Type:
measured neutral current || calculated ground current
Type Of Measurement:
current || voltage || frequency || power factor || energy || active and reactive power
Number Of Outputs:
2 digital
Ambient Air Temperature For Storage:
-40-85°C
Frequency Measurement Range:
45-65 Hz
Accuracy Class:
class 0.2S active energy IEC 62053-22
Net Weight:
450 g
Country of Origin:
India
Weight:
450 g
Device Application:
gateway || WAGES metering || power monitoring || multi-tariff
Line Rated Current:
1 A || 5 A
Ambient Air Temperature For Operation:
-25-70°C
[Us] Rated Supply Voltage:
100...300 V DC || 90...528 V AC 45...65 Hz
Power Quality Analysis:
up to the 63rd harmonic || waveform capture || voltage sag and swell detection
Display Type:
monochrome graphic LCD
Number Of Inputs:
4 digital
Poles Description:
3P + N || 3P || 1P + N
China Rohs Regulation:
X
Ride-Through Time:
35 ms 120 V AC typical || 129 ms 230 V AC typical || 50 ms 125 V DC typical
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ip Degree Of Protection:
IP54 display: conforming to IEC 60529 || IP30 rear: conforming to IEC 60529
Product Certifications:
CE conforming to IEC 61010-1 || cULus conforming to UL 61010-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
$4,646.35

Description

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.2S accuracy per IEC 62053-22 standard and 128 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 63rd Harmonic. Include 1.1 MegaBytes of memory for up to 14 selectable parameters with configurable interval and duration. This meter also feature the direct monitoring of neutral current plus an advanced waveform capture with sag and swell detection. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 480 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20 to 690 VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 45 to 65 Hz. Communication protocol are Modbus RTU and ASCII 2 wires with RS485 port support plus Modbus TCP/IP, Ethernet/IP and BACnet/IP based on 10/100 Mbit/s, daisy chain Ethernet with RJ45 port support. The embedded communication capabilities allow the support of the DNP 3.0 protocol, the access to an onboard web server and a Serial to Ethernet gateway. The meter also has four digital inputs with WAGES support and two digital outputs. There are 52 configurable alarms and it supports eight tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 3.03 inches (77 millimetres), height 3.78 inches (96 millimetres) and product weight 15.9 onces (450 g).
View AllClose