90...415 V AC 45...65 Hz +/- 10 % || 110...415 V DC +/- 10 %
Ambient Air Temperature For Operation:
-25-70°C
Power Quality Analysis:
EN 50160 2010 compliance report || IEEE 519 2014 compliance report || up to the 63rd harmonic || harmonic distortion || waveform capture || voltage sag and swell detection || programmablity (logic and math functions) || IEC 62586 power quality m
Electromagnetic Compatibility:
electrostatic discharge conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 || electrical fast transient/burst immunity test conforming to IEC 61000-4-4 || surge immunity test confor
Depth:
77.5 mm
Number Of Inputs:
3 digital 30 V AC || 3 digital 60 V DC
Mounting Mode:
flush-mounted
Line Rated Current:
1 A || 5 A || 10 A
Measurement Voltage:
57-400 V AC 42...69 Hz between phase and neutral || 100-690 V AC 42...69 Hz between phases
Cybersecurity:
enable/disable communication ports || password protection || Syslog protocol support || robust security logs || port hardening
Web Services:
customizable home page || file upload/download via FTP || file upload/download via SFTP || web server || alarm notification by e-mail || viewing of captured waveform (FTP) || viewing of captured waveform (web) || HTTPS server
Memory Capacity:
64 MB
Ip Degree Of Protection:
IP54 front: conforming to IEC 60529 || IP30 body: conforming to IEC 60529
current || voltage total || frequency || active and reactive power total || apparent power total || power factor total || active and reactive power per phase, rms || apparent power per phase, rms || power factor per phase, rms
Operating Altitude:
9842.52 ft (3000 m)
Display Type:
colour TFT LCD
Sampling Rate:
128 samples/cycle
Width:
96 mm
Mounting Support:
framework
Measurement Current:
50-10000 mA
Communication Port Support:
ETHERNET || screw terminal block RS485
Analogue Input Type:
voltage (impedance 5 MOhm) || current (impedance 0.3 mOhm)
Installation Category:
III
Display Resolution:
320 x 240 pixels QVGA
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Net Weight:
581 g
Isolation Voltage:
III400-690 V conforming to IEC 61010-1:ed. 3 || III400-690 V conforming to EN 61010-1:ed. 3 || III347-600 V conforming to UL 61010-1:ed. 3 || III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
Weight:
581 g
Data Recording:
min/max of instantaneous values || waveform logs || sequence of event recording || time stamping || alarm logs || trending/forecasting || sag and swell logs || harmonics logs || GPS synchronisation || data logs || event logs || 10 data recorders
Communication Service:
SMTP e-mail notification || RSTP support || NTP time synchronization || DHCP || PTP time synchronization
Network Frequency:
50 Hz || 60 Hz
Measurement Accuracy:
current +/- 0.1 % || voltage +/- 0.1 % || active energy +/- 0.2 %
Accuracy Class:
class 0.2S active energy IEC 62053-22 || class 0.2 active energy ANSI C12.20 || class 0.2 active power IEC 61557-12 || class 0.5S reactive energy IEC 62053-24 || class 0.5 power factor IEC 61557-12 || class 0.2 voltage IEC 61557-12 || class 0.2 curre