Schneider Electric

Schneider Electric MGF26400 Circuit breaker, PowerPacT M, 400A, 2 pole, 600VAC, 18kA, busbar, ET 1.0, 80%

(No reviews yet) Write a Review
SKU:
MGF26400
MPN:
MGF26400
Condition:
New
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Electrical Connection:
busbar connection, line || busbar connection, load
Sustainable Offer Status:
Green Premium product
Control Type:
operating handle
Network Frequency:
50/60 Hz
Long Time Pick-Up Adjustment Range:
300...800 A
Pvc Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mercury Free:
Yes
Quantity Per Set:
1
Device Application:
distribution
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Magnetic Tripping Current:
800-4000 A
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Support:
busbar
Product Or Component Type:
circuit breaker
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact M
Height:
12.86 in
Color:
Black
Trip Unit Technology:
electronic, basic, ET 1.0,
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Ip Degree Of Protection:
IP40
Local Signaling:
1 trip indicator green)
Wire Stripping Length:
25 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Depth:
8.05 in
Poles Description:
2P
Ambient Air Temperature For Operation:
-25-70°C
Terminal Identifier:
AL800M23K
Length:
25 mm
Ambient Air Temperature For Storage:
-50-85°C
Warranty:
18 months
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Line Rated Current:
400-400 A
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206030EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Country of Origin:
United States
Net Weight:
29 lb(US)
Environmental Disclosure:
ENVPEP2206030EN
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Breaking Capacity Code:
G
$5,960.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has a busbar connection. This PowerPacT M, 400A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.