Schneider Electric

Schneider Electric NQ42L2 Panelboard interior, NQ, main lugs, 225A, Al bus, 42 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ42L2
MPN:
NQ42L2
Condition:
New
Standards:
CSA || UL
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
Height:
33.00 in
Warranty:
18 months
Tightening Torque:
4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AW
Enclosure Nominal Height:
38 in
Mercury Free:
Yes
Phase:
1 phase 3 wires
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Width:
10.44 in
Toxic Heavy Metal Free:
Yes
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Width:
20 in
Load Center Type:
main lugs
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc:
Yes
Product Or Component Type:
interiors
Circularity Profile:
N/A
Country of Origin:
Mexico
Eu Rohs Directive:
Compliant
Line Rated Current:
225 A
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Circuit Breaker Type:
QOB || QOB-VH || QHB
Enclosure Nominal Width:
20 in
Number Of Spaces:
42
Environmental Disclosure:
ENVPEP1404019EN
Height:
38 in
Material:
aluminium
$1,340.00

Description

NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for nonlinear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 225 A single phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 3 wire system with 42 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Interior is 33 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
View AllClose