Schneider Electric

Schneider Electric NQ42L4 Panelboard interior, NQ, main lugs, 400A, Al bus, 42 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ42L4
MPN:
NQ42L4
Condition:
New
Warranty:
18 months
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
Line Rated Current:
400 A
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Toxic Heavy Metal Free:
Yes
Material:
aluminium
Enclosure Nominal Width:
20 in
Width:
10.44 in
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
interiors
Eu Rohs Directive:
Compliant
Enclosure Nominal Height:
50 in
Rohs Exemption Information:
Yes
Circularity Profile:
N/A
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc:
Yes
Height:
50 in
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Width:
20 in
Mercury Free:
Yes
Country of Origin:
Mexico
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Phase:
1 phase 3 wires
Environmental Disclosure:
ENVPEP1404019EN
Standards:
UL || CSA
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Circuit Breaker Type:
QOB || QOB-VH || QHB
Load Center Type:
main lugs
Height:
45 in
Tightening Torque:
31.07-33.90 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 31.07-33.90 N.m 53.48-177.3 mm² (AWG 1/0...350 kcmil) || 62.14-62.14 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 62.14-62.14 N.m 53.48-152 mm² (AWG 1/0...300 kcmil) || 42.37-42.37 N.m 53.48-380 mm
Number Of Spaces:
42
$1,778.00

Description

NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for nonlinear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 225 A single phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 3 wire system with 42 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Interior is 33 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
View AllClose