Schneider Electric

Schneider Electric NQ430L1 Panelboard interior, NQ, main lugs, 100A, Al bus, 30 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ430L1
MPN:
NQ430L1
Condition:
New
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Warranty:
18 months
Phase:
3 phase 4 wires
Tightening Torque:
4.52-5.65 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 11.3-11.3 N.m 13.30-67.43 mm² (AWG 6...AWG 2/0) || 31.07-31.07 N.m 13.30-177.3 mm² (AWG 6...350 kcmil) || 31.07-31.07 N.m 13.30-126.7 mm² (AWG 6...250 kcmil) || 31.07-31.07 N.m 107.2-152 mm² (AWG 4..
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Environmental Disclosure:
ENVPEP1404019EN
Height:
32 in
Number Of Spaces:
30
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Load Center Type:
main lugs
Standards:
CSA || UL
Country of Origin:
Mexico
Toxic Heavy Metal Free:
Yes
Eu Rohs Directive:
Compliant
Connections - Terminals:
lug line AWG 6...AWG 2/0 aluminium || lug neutral AWG 6...AWG 2/0 aluminium
Line Rated Current:
100 A
Circularity Profile:
N/A
Height:
27 in
Sustainable Offer Status:
Green Premium product
Width:
20 in
Product Or Component Type:
interiors
Mercury Free:
Yes
Width:
10.44 in
Reach Free Of Svhc:
Yes
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Enclosure Nominal Width:
20 in
Circuit Breaker Type:
QOB || QOB-VH || QHB
Enclosure Nominal Height:
32 in
Rohs Exemption Information:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
Material:
aluminium
$1,112.00

Description

NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for non-linear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 100 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 30 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Lug connections will accept 6 AWG to 2/0 AWG aluminum wire. Interior is 27 inches tall and 10.44 inches wide. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
View AllClose