Schneider Electric

Schneider Electric NQ442L4 Panelboard interior, NQ, main lugs, 400A, Al bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ442L4
MPN:
NQ442L4
Condition:
New
Line Rated Current:
400 A
Environmental Disclosure:
ENVPEP1404019EN
Reach Free Of Svhc:
Yes
Eu Rohs Directive:
Compliant
Phase:
3 phase 4 wires
Number Of Spaces:
42
Toxic Heavy Metal Free:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rohs Exemption Information:
Yes
Height:
50 in
Circularity Profile:
N/A
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Enclosure Nominal Width:
20 in
Country of Origin:
Mexico
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Load Center Type:
main lugs
Mercury Free:
Yes
Circuit Breaker Type:
QOB || QOB-VH || QHB
Width:
20 in
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Enclosure Nominal Height:
50 in
Tightening Torque:
31.07-33.90 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 31.07-33.90 N.m 53.48-177.3 mm² (AWG 1/0...350 kcmil) || 62.14-62.14 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 62.14-62.14 N.m 53.48-152 mm² (AWG 1/0...300 kcmil) || 42.37-42.37 N.m 53.48-380 mm
Material:
aluminium
Height:
45 in
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Connections - Terminals:
lug line AWG 1/0...750 kcmil aluminium || lug neutral AWG 1/0...750 kcmil aluminium
Standards:
CSA || UL
Warranty:
18 months
Width:
10.44 in
Sustainable Offer Status:
Green Premium product
$2,012.00

Description

NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboard interiors are field convertible to top or bottom feed. NQ Panelboards are convertible from main lug to main breaker. NQ Panelboards provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. This interior provides protection for your commercial and industrial applications. The main lugs are rated at 400A, 240 VAC 3 phase or 48 VDC. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 42 spaces and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. Lug connections will accept two 1/0 AWG to 750 kcmil aluminum wire. Interior is 45 inches tall and 10.44 inches wide. This NQ panelboard interior is UL listed and CSA certified.
View AllClose