Schneider Electric

Schneider Electric NQ472L4 Panelboard interior, NQ, main lugs, 400A, Al bus, 72 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ472L4
MPN:
NQ472L4
Condition:
New
Connections - Terminals:
lug line AWG 1/0...750 kcmil aluminium || lug neutral AWG 1/0...750 kcmil aluminium
Eu Rohs Directive:
Compliant
Enclosure Nominal Height:
62 in
Rohs Exemption Information:
Yes
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Mercury Free:
Yes
Height:
62 in
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Load Center Type:
main lugs
Circularity Profile:
N/A
Tightening Torque:
31.07-33.90 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 31.07-33.90 N.m 53.48-177.3 mm² (AWG 1/0...350 kcmil) || 62.14-62.14 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 62.14-62.14 N.m 53.48-152 mm² (AWG 1/0...300 kcmil) || 42.37-42.37 N.m 53.48-38
Line Rated Current:
400 A
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Enclosure Nominal Width:
20 in
Warranty:
18 months
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Standards:
CSA || UL
Country of Origin:
Mexico
Net Weight:
13.608 kg
Circuit Breaker Type:
QOB || QOB-VH || QHB
Environmental Disclosure:
ENVPEP1404019EN
Sustainable Offer Status:
Green Premium product
Toxic Heavy Metal Free:
Yes
Material:
aluminium
Reach Free Of Svhc:
Yes
Width:
10.44 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Width:
20 in
Weight:
13.608 kg
Number Of Spaces:
72
Phase:
3 phase 4 wires
Product Or Component Type:
interiors
Height:
57 in
$3,449.00

Description

NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for nonlinear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 400 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 72 circuits and has an aluminum bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Interior is 57 inches tall and 10.44 inches wide. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.