Schneider Electric

Schneider Electric NQ472L4C Panelboard interior, NQ, main lugs, 400A, Cu bus, 72 pole spaces, 3 phase, 4 wire, 240 VAC, 48VDC

(No reviews yet) Write a Review
SKU:
NQ472L4C
MPN:
NQ472L4C
Condition:
New
Rohs Exemption Information:
Yes
Load Center Type:
main lugs
Enclosure Nominal Depth:
5.75 in NEMA 1 || 6.5 in NEMA 3R/5/12
Product Or Component Type:
interiors
Material:
copper
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Tightening Torque:
31.07-33.90 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 31.07-33.90 N.m 53.48-177.3 mm² (AWG 1/0...350 kcmil) || 62.14-62.14 N.m 53.48-380 mm² (AWG 1/0...750 kcmil) || 62.14-62.14 N.m 53.48-152 mm² (AWG 1/0...300 kcmil) || 42.37-42.37 N.m 53.48-380 mm
Phase:
3 phase 4 wires
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Iu] Rated Interrupted Current:
10 kA || 22 kA || 65 kA
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Height:
62 in
Circularity Profile:
N/A
Connections - Terminals:
lug line AWG 1/0...750 kcmil aluminium || lug neutral AWG 1/0...750 kcmil aluminium
Warranty:
18 months
Environmental Disclosure:
ENVPEP1404010EN
Width:
10.44 in
Reach Free Of Svhc:
Yes
Number Of Spaces:
72
Enclosure Nominal Width:
20 in
Country of Origin:
United States
Circuit Breaker Type:
QOB || QOB-VH || QHB
Height:
57 in
Enclosure Nominal Height:
62 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive ha
Line Rated Current:
400 A
Width:
20 in
[Ue] Rated Operational Voltage:
240 V AC || 48 V DC
Standards:
UL || CSA
$3,657.00

Description

NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboards provide 200% rated neutrals for nonlinear loads. NQ Panelboards are convertible from main lug to main breaker. Interior has a maximum voltage rating of 240 VAC and 48 VDC. This NQ Panelboard interior has a main lug and is rated at 400 A three phase. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 72 circuits and has a copper bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. This interior provides protection for your commercial and industrial applications. NQ Panelboard interiors are field convertible to top or bottom feed. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. Interior is 57 inches tall and 10.44 inches wide. Lug connections will accept 1/0 AWG to 750 kcmil aluminum wire. This interior is UL listed and CSA certified. NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices.
View AllClose