Schneider Electric

Schneider Electric PGA36040CU33A Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0, 100%, ABC

(No reviews yet) Write a Review
SKU:
PGA36040CU33A
MPN:
PGA36040CU33A
Condition:
New
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Height:
9 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Phase Connection:
ABC
Ambient Air Temperature For Storage:
-50-85°C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Continuous Current Rating:
1
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-25-70°C
Sustainable Offer Status:
Green Premium product
Device Application:
distribution
Trip Unit Name:
MicroLogic 5.0
Control Type:
toggle
Circuit Breaker Application:
HACR rated
Line Rated Current:
400-400 A
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Pollution Degree:
3 IEC 60947-1
Quality Labels:
CE
Local Signaling:
1 trip indicator green)
Poles Description:
3P
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Range:
PowerPact
Mercury Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206033EN
Product Certifications:
UL || CSA || NOM
Net Weight:
32 lb(US)
Rohs Exemption Information:
Yes
Terminal Identifier:
AL800M23K
Eu Rohs Directive:
Compliant with Exemptions
Depth:
8.05 in
Electrical Connection:
I-Line connection, line || lugs, load
Mounting Mode:
I-Line bracket)
Country of Origin:
United States
Weight:
32 lb(US)
Height:
12.86 in
Wire Stripping Length:
25 mm
Length:
25 mm
Ip Degree Of Protection:
front cover IP40
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Network Frequency:
50/60 Hz
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Support:
bracket
Warranty:
18 months
Product Name:
PowerPact P
Circularity Profile:
ENVEOLI2206033EN
$34,191.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose