Schneider Electric

Schneider Electric PGA36080U31B Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0, 80%, ABC

(No reviews yet) Write a Review
SKU:
PGA36080U31B
MPN:
PGA36080U31B
Condition:
New
Circularity Profile:
ENVEOLI2206033EN
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Weight:
32 lb(US)
Range:
PowerPact
Height:
12.86 in
Sustainable Offer Status:
Green Premium product
Circuit Breaker Application:
HACR rated
Mounting Mode:
I-Line bracket)
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Continuous Current Rating:
0.8
Quantity Per Set:
1
Country of Origin:
Mexico
Local Signaling:
overload 1 1 LED amber) || 1 trip indicator green)
Product Or Component Type:
circuit breaker
Height:
9 in
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Wire Stripping Length:
25 mm
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Net Weight:
32 lb(US)
Eu Rohs Directive:
Compliant with Exemptions
Product Name:
PowerPact P
Mercury Free:
Yes
Breaking Capacity Code:
G
Phase Connection:
ABC
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Quality Labels:
CE
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Poles Description:
3P
Network Frequency:
50/60 Hz
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Ambient Air Temperature For Storage:
-50-85°C
Trip Unit Name:
MicroLogic 3.0
Mounting Support:
bracket
Environmental Disclosure:
ENVPEP2206033EN
Terminal Identifier:
AL800M23K
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
UL || CSA || NOM
Device Application:
distribution
$15,390.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.