Schneider Electric

Schneider Electric PGA36120U33A Circuit breaker, PowerPacT P, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0, 80%, ABC

(No reviews yet) Write a Review
SKU:
PGA36120U33A
MPN:
PGA36120U33A
Condition:
New
Wire Stripping Length:
30 mm
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Height:
9 in
Weight:
32 lb(US)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Length:
30 mm
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206033EN
Rohs Exemption Information:
Yes
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Operation:
-25-70°C
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Support:
bracket
Control Type:
toggle
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
Ambient Air Temperature For Storage:
-50-85°C
Ip Degree Of Protection:
front cover IP40
Quantity Per Set:
1
Mounting Height:
9 in
Range:
PowerPact
Local Signaling:
overload 1 1 LED amber) || 1 trip indicator green)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Trip Unit Name:
MicroLogic 5.0
Product Name:
PowerPact P
Product Or Component Type:
circuit breaker
Warranty:
18 months
Net Weight:
32 lb(US)
Continuous Current Rating:
0.8
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Phase Connection:
ABC
Circularity Profile:
ENVEOLI2206033EN
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Device Application:
distribution
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Network Frequency:
50/60 Hz
Line Rated Current:
1200-1200 A
Terminal Identifier:
AL1200P25K
Depth:
8.05 in
Height:
16.16 in
Circuit Breaker Application:
HACR rated
Poles Description:
3P
$21,131.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose