Schneider Electric

Schneider Electric PGL36040U31A Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 18kA, lugs, Micrologic 3.0, 80%

(No reviews yet) Write a Review
SKU:
PGL36040U31A
MPN:
PGL36040U31A
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Wire Stripping Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Pvc Free:
Yes
Ip Degree Of Protection:
front cover IP40
Local Signaling:
overload 1 1 LED amber) || 1 trip indicator green)
Pollution Degree:
3 IEC 60947-1
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Quality Labels:
CE
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Warranty:
18 months
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Range:
PowerPact
Ambient Air Temperature For Storage:
-50-85°C
Circuit Breaker Application:
HACR rated
Length:
25 mm
Environmental Disclosure:
ENVPEP2206033EN
Net Weight:
32 lb(US)
Poles Description:
3P
Country of Origin:
United States
Breaking Capacity Code:
G
Rohs Exemption Information:
Yes
Continuous Current Rating:
0.8
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Name:
MicroLogic 3.0
Terminal Identifier:
AL800M23K
Eu Rohs Directive:
Compliant with Exemptions
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Network Frequency:
50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
toggle
Quantity Per Set:
1
Depth:
8.05 in
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Weight:
32 lb(US)
Ambient Air Temperature For Operation:
-25-70°C
Line Rated Current:
400-400 A
Mercury Free:
Yes
Electrical Connection:
lugs, load || lugs, line
Device Application:
distribution
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
$14,693.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose