Schneider Electric

Schneider Electric PGL36060U43A Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 18kA, lugs, Micrologic 5.0A, 80%

(No reviews yet) Write a Review
SKU:
PGL36060U43A
MPN:
PGL36060U43A
Condition:
New
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Eu Rohs Directive:
Compliant with Exemptions
Local Signaling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Poles Description:
3P
Pvc Free:
Yes
Pollution Degree:
3 IEC 60947-1
Quantity Per Set:
1
Device Application:
distribution
Depth:
8.05 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Terminal Identifier:
AL800M23K
Circuit Breaker Application:
HACR rated
Product Name:
PowerPact P
Line Rated Current:
600-600 A
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mercury Free:
Yes
Country of Origin:
Italy
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Ambient Air Temperature For Operation:
-25-70°C
Trip Unit Technology:
electronic, ammeter, MicroLogic 5.0 A, LSI
Quality Labels:
CE
Rohs Exemption Information:
Yes
Electrical Connection:
lugs, load || lugs, line
Product Or Component Type:
circuit breaker
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Product Certifications:
UL || CSA || NOM
Wire Stripping Length:
25 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Name:
MicroLogic 5.0 A
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Ip Degree Of Protection:
front cover IP40
Continuous Current Rating:
0.8
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
G
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Warranty:
18 months
Length:
25 mm
Control Type:
toggle
Range:
PowerPact
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Environmental Disclosure:
ENVPEP2206033EN
Net Weight:
32 lb(US)
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
$17,043.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose